Automated method for determination of serum 5'-nucleotidase activity.

نویسندگان

  • V G Bethune
  • M Fleisher
  • M K Schwartz
چکیده

An automated method has been devised for determining 5’-nucleotidase activity in serum. A modified creatine phosphokinase cartridge (Technicon Instrument Corp., Tarrytown, N. Y.) is used to prepare a reaction mixture containing, per liter: barbital buffer (pH 7.5), 16.1 mmol; adenosine-5’-phosphate, 5.4 mmol; Mg2, 20.2 mmol; phenyl phosphate, 7.8 mmol; adenosine deamlnase, 0.78 mg; and sample, 0.21 mI/mI of reaction mixture. After incubation, the liberated ammonium ion is determined by use of the alkaline hypochlorite-phenol reaction. N ucleotidase activity as determined by the automated method correlated well with activities as determined manually by a Ni2 inhibition-phosphate analysis procedure. Respective values obtained by the manual and by this procedure were: for sera with activities within the normal range, 7.9 ± 3.2 and 8.2 ± 3.3 U/liter; for activities between 16 and 50 U/liter, 26.3 ± 9.3 and 26.5 ± 8.8 U/liter; and for serum with activities greater than 50 U/liter, 79.1 ± 42.5 and 78.7 ± 41.3 U/liter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple, direct determination of serum 5'-nucleotidase.

A simple determination of 5'-Nucleotidase in blood serum without deproteinization is described. The enzyme activity is distinguished from that of a nonspecific alkaline phosphatase by nickel inhibition and the inorganic phosphate released from adenosine monophosphate used as substrate is determined by a method previously described. Additional studies include the determination of optimal conditi...

متن کامل

Determination of serum 5'-nucleotidase with a centrifugal analyzer.

We describe a multi-point method for the determination of the serum enzyme activity 5'-nucleotidase by means of an NADH sensor reaction. Studies show that the assay may be carried out in one step, without preincubation, by using a GEMSAEC Fast Analyzer.

متن کامل

Inhibition by concanavalin A as the basis for a specific assay of serum 5'-nucleotidase activity.

Concanavalin A inhibits serum 5'-nucleotidase activity, without causing significant inhibition of alkaline phosphatase activity. This observation serves as the basis for a new method for assaying the 5'-nucleotidase activity in serum, which depends upon the difference between the enzymic hydrolysis of adenosine-5'-monophosphate in the presence and absence of concanavalin A. A denosine released ...

متن کامل

Colorimetric determination of serum 5'-nucleotidase without deproteinization.

We present a sensitive colorimetric determination of 5'-nucleotidase based on the measurement of liberated phosphate by reaction with stannous chloride/molybdenum blue. No protein precipitation is required. The method is simple, sensitive, economical, and easy to use, and involves relatively stable reagents.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 18 12  شماره 

صفحات  -

تاریخ انتشار 1972