Unreliable detection of Mycobacterium xenopi by the nonradiometric Bactec MGIT 960 culture system.

نویسندگان

  • Claudio Piersimoni
  • Domenico Nista
  • Stefano Bornigia
  • Giancarlo Gherardi
چکیده

From June 2006 to December 2007, 3,648 clinical specimens consecutively received for mycobacterial culture were investigated. Each processed sample was inoculated into Bactec MGIT 960 liquid medium and a Löwenstein-Jensen slant. Tubes that were flagged as positive by the instrument as well as those determined to be negative after 42 days of incubation were removed, visually inspected for growth, and checked for the presence of acid-fast bacilli. Three hundred sixty-nine mycobacterial strains were recovered; of the 44 Mycobacterium xenopi isolates recovered by MGIT medium, only 13 were detected by the instrument (P<0.0001). Most tubes yielding M. xenopi exhibited a peculiar pattern of growth characterized by a scant number of round, yellow-pigmented granules instead of the fine, evenly dispersed clumps usually observed for mycobacteria. It is suggested to check all individual tubes discarded by the MGIT 960 system at the end of the incubation period to prevent a significant amount of previously undetected growth from being missed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of BACTEC MGIT 960 for recovery of mycobacteria from clinical specimens: multicenter study.

The BACTEC MGIT 960 instrument is a fully automated system that exploits the fluorescence of an oxygen sensor to detect growth of mycobacteria in culture. Its performance was compared to those of the radiometric BACTEC 460 instrument and egg-based Lowenstein-Jensen medium. An identical volume of sample was inoculated in different media, and incubation was carried out for 6 weeks with the automa...

متن کامل

Growth detection failures by the nonradiometric Bactec MGIT 960 mycobacterial culture system.

Mycobacterial growth in liquid culture can go undetected by automated, nonradiometric growth detection systems. In our laboratory, instrument-negative tubes from the Bactec MGIT 960 system are inspected visually for clumps suggestive of mycobacterial growth, which (if present) are examined by acid-fast smear analysis. A 3-year review demonstrated that ∼1% of instrument-negative MGIT cultures co...

متن کامل

Multicenter evaluation of fully automated BACTEC Mycobacteria Growth Indicator Tube 960 system for susceptibility testing of Mycobacterium tuberculosis.

The reliability of the BACTEC Mycobacteria Growth Indicator Tube (MGIT) 960 system for testing of Mycobacterium tuberculosis susceptibility to the three front-line drugs (isoniazid [INH], rifampin [RIF], and ethambutol [EMB]) plus streptomycin (STR) was compared to that of the BACTEC 460 TB system. The proportion method was used to resolve discrepant results by an independent arbiter. One hundr...

متن کامل

Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium.

Using two different liquid media and one conventional solid medium, a total of 57 mycobacterial isolates (Mycobacterium tuberculosis, n = 55; nontuberculous mycobacteria, n = 2) were recovered from 377 clinical specimens. The rates of recovery of M. tuberculosis were 96. 4% with the BACTEC MGIT 960 liquid medium, 92.7% with BACTEC 12B liquid medium, and 81.8% with the Löwenstein-Jensen (LJ) med...

متن کامل

Multicenter laboratory validation of the BACTEC MGIT 960 technique for testing susceptibilities of Mycobacterium tuberculosis to classical second-line drugs and newer antimicrobials.

The BACTEC MGIT 960 system, a fully automated, nonradiometric, noninvasive system for detection and drug susceptibility testing of mycobacteria, was evaluated for the ability to test susceptibilities to second-line drugs. In this study, which was carried out in three phases (phase I, mostly susceptible strains; phase II, mostly resistant strains; phase III, final testing of the optimal drug con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2009