Is repetitive intraoperative splash basin use a source of bacterial contamination in total joint replacement?

نویسندگان

  • Sergio A Glait
  • Ran Schwarzkopf
  • Steven Gould
  • Joseph Bosco
  • James Slover
چکیده

Splash basins are used in arthroplasty cases to wash instruments. Several studies in the literature have shown these basins being a potential source of bacterial infection. This study assesses the risk of contamination of intraoperative splash basins used to wash and store instruments. A total of 46 random clean primary arthroplasty cases (32 hips, 13 knees, and 1 unicondylar knee) were studied by taking cultures of sterile splash basins as soon as they are opened (controls) and again at wound closure after instruments and debris have come into contact with the sterile water. All cultures were taken with sterile culture swabs and sent to the laboratory for aerobic, anaerobic, and fungal culture. Outcome measured was any positive culture. A total of 92 cultures from 46 cases were tested. Only 1 (2.17%) control culture, which grew Streptococcus viridans, was positive for bacterial growth. One of 46 samples (2.17%) taken at wound closure was positive for coagulase-negative Staphylococcus. Mean time between basin opening and wound closure was 180±45 minutes. For the 1 infected sample taken at the conclusion of the case, it was 240 minutes. Previous studies show contamination rates as high as 74% for splash basins used intraoperatively. Our study contradicts the belief that splash basins are a high source of infection, with only 2.17% of basins showing contamination. Splash basins can be a potential source of contamination, but the risk is not as high as previously cited in the orthopedic literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sterile Parts of Operating Gown during Lower Limb Joint Replacement Surgery

Background: The prevention of surgical site infection is one of the most concerning issues in operating rooms. Surgicalgowns are worn as one of the intraoperative strategies for infection prevention. The present study investigated whetherthe gowns remained sterile during the surgical procedure. Furthermore, this study examined which parts of the surgicalgown were more prone to...

متن کامل

Bacterial contamination of the wound during primary total hip and knee replacement

BACKGROUND AND PURPOSE Previous work has shown that despite preventive measures, intraoperative contamination of joint replacements is still common, although most of these patients seem to do well in follow-up of up to 5 years. We analyzed the prevalence and bacteriology of intraoperative contamination of primary joint replacement and assessed whether its presence is related to periprosthetic j...

متن کامل

The Use of Antibiotic Impregnated Cement Spacers in the Treatment of Infected Total Joint Replacement: Challenges and Achievements

Two stage total hip arthroplasty revision surgery includes foreign material debridment, insertion of antibiotic impregnatedcement spacer, and finally, reimplantation of the prosthesis. This review has aimed to evaluate the efficacy of antibioticimpregnated cement spacers in infection control and eradication in arthroplasties.A total of 85 articles on total hip arthroplasty wer...

متن کامل

Intraoperative bacterial contamination in operations for joint replacement.

All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also con...

متن کامل

Splash in elective primary knee and hip replacement: are we adequately protected?

An intra-operative splash is a common occurrence in elective knee and hip replacement surgery and can potentially transmit bloodborne diseases, with devastating consequences. This study aimed to quantify the risk of a splash and to assess its correlation with body mass index, duration of surgery and the volume of lavage fluid used. Between December 2007 and April 2008, 62 consecutive patients (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 34 9  شماره 

صفحات  -