A highly sensitive and rapid radioimmunoassay for the determination of arginine8-vasopressin.
نویسندگان
چکیده
A highly sensitive radioimmunossay for arginine8-vasopressin (argipressin; INN) measurement was developed using Amberlite XAD 2 resin columns to extract arginine8-vasopressin from acidified human plasma. Arginine8-vasopressin was determined by a rapid radioimmunoassay method (2 x 20 h) using a specific antibody and 125I-labelled antigen. The bound fraction was separated by adsorption of the free fraction onto bovine serum albumin-coated charcoal; this resulted in low unspecific binding of less than 2%. Recovery experiments in the physiological range resulted in a mean (+/- SEM) recovery of 88 +/- 3%. The radioimmunoassay consistently yielded a detection limit of 0.3 ng/l (ED90) and a mean 50% binding intercept (ED50) of 3.5 ng/l. Arginine8-vasopressin immunoreactivity was characterized by reverse-phase high performance liquid chromatography, which confirmed the specificity of the assay. Serial plasma dilution curves paralleled the standard curve. The intra- and inter-assay variations were 9.4% and 15%, respectively. Arginine8-vasopressin concentrations in healthy subjects were determined in normal hydration status (2.2 +/- 0.3 ng/l; n = 11), as well as during suppression by water immersion (1.5 +/- 0.2 ng/l; n = 11) or by water loading (1.6 +/- 0.2 ng/l; n = 8). Thus, this assay allows for a sensitive, accurate and rapid quantification of plasma arginine8-vasopressin concentrations.
منابع مشابه
DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES
Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...
متن کاملImproved extraction procedure and RIA for determination of arginine8-vasopressin in plasma: role of premeasurement sample treatment and reference values in children.
We optimized an RIA for measurement of arginine8-vasopressin (AVP) in plasma by use of 100-mg Isolute C18 columns for extraction, addition of a preincubation step, and use of maximal dilution of a commercially available antiserum. The detection limit was 0.06 ng/L when 0.5 mL of acidified plasma was extracted. The within- and between-run CVs (n = 16) at physiological concentrations were 5.8-10....
متن کاملA sensitive method for electrochemical determination of molybdenum (VI) in plant foodstuff samples using Ni0.5Zn0.5Fe2O4 nanocomposite modified carbon paste electrode
In the present study, a new chemically modified carbon paste electrode (CPE) is constructed for rapid, accurate, simple, highly sensitive, and selective determination of Mo (VI) using differential pulse voltammetry. The electrode was prepared using magnetic nickel zinc ferrite nanocomposite (Ni0.5Zn0.5Fe2O4), as the modifier in CPE (Ni0.5Zn0.5Fe2O4/CPE). Mo (VI) was determined after preconcentr...
متن کاملApplication of Thionine Dye for Highly Sensitive and Selective Catalytic kinetic Determination of Osmium
Anew, highly sensitive and selective catalytic kinetic method (CKM) for determination of osmium (VIII) has been established based on its catalytic effect on the oxidation of thionine dye by hydrogen peroxide in alkaline medium. The reaction has been followed spectrophotometrically by measuring the decrease in the absorbance band of thionine at 600 nm. Under the optimum conditions, the proposed ...
متن کاملDetermination of Strontium Ion in Depilatory Powder, Toothpaste, and Raticide Samples using a Novel and Highly Sensitive Potentiometric Sensor Coupled with a Central Composite Design
The strontium ion, in water-soluble forms, is one of the major pollutant in drinking water. Therefore, a simple, rapid, selective, and sensitive potentiometric carbon paste electrode was developed to measure strontium ion in real samples with complex matrices. To prepare the potentiometric sensor, a synthetic ligand ((E)-4-(((2-amino-4-chlorophenyl)imino)methyl)-5-(hydroxymethyl)-2-methyl pyrid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies
دوره 30 4 شماره
صفحات -
تاریخ انتشار 1992