An electrochemical sensing platform based on local repression of electrolyte diffusion for single-step, reagentless, sensitive detection of a sequence-specific DNA-binding protein.
نویسندگان
چکیده
In this paper, we report for the first time an electrochemical biosensor for single-step, reagentless, and picomolar detection of a sequence-specific DNA-binding protein using a double-stranded, electrode-bound DNA probe terminally modified with a redox active label close to the electrode surface. This new methodology is based upon local repression of electrolyte diffusion associated with protein-DNA binding that leads to reduction of the electrochemical response of the label. In the proof-of-concept study, the resulting electrochemical biosensor was quantitatively sensitive to the concentrations of the TATA binding protein (TBP, a model analyte) ranging from 40 pM to 25.4 nM with an estimated detection limit of ∼10.6 pM (∼80 to 400-fold improvement on the detection limit over previous electrochemical analytical systems).
منابع مشابه
Design of Biosensors Based Transition-Metal Dichalcogenide for DNA-base Detection: A First-Principles Density Functional Theory Study
The main function purpose of nanobiosensors is to sense a biologically specific material and the kind of sensing platform and doping engineering has been an emerging topic and plays an important role in monolayer molybdenum disulfide (mMoS2). In this paper, we theoretically reveal the electronic structures of mMoS2 doped by 3d transition metals. Furthermore, adsorption of nucleic acid [Adenine ...
متن کاملUsing an electrochemical nanobiosensor based on titanium carbide-carbon nanotubes polymeric nanocomposite for the epithelialovarian cancer early detection
Background & Aim: Ovarian cancer is the most lethal among female malignancies. So far, treatment improvements have affected patient survival, but it is still more important to provide an early diagnosis that can detect the disease in its early stages. Therefore, introducing a rapid, accurate, and low-cost method to disease detection can be important and necessary. Methods: This study introduce...
متن کاملAn Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions
In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...
متن کاملAn electrochemical sensor for single nucleotide polymorphism detection in serum based on a triple-stem DNA probe.
We report here an electrochemical approach that offers, for the first time, single-step, room-temperature single nucleotide polymorphism (SNP) detection directly in complex samples (such as blood serum) without the need for target modification, postwashing, or the addition of exogenous reagents. This sensor, which is sensitive, stable, and reusable, is comprised of a single, self-complementary,...
متن کاملA reagentless and reusable electrochemical DNA sensor based on target hybridization-induced stem-loop probe formation.
We report a reagentless and reusable electrochemical DNA sensor that exploits competitive binding and target hybridization-induced change in the signalling probe conformation for robust detection of a target DNA sequence.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 139 9 شماره
صفحات -
تاریخ انتشار 2014