The influence of tip shape on bending force during needle insertion
نویسندگان
چکیده
Steering of needles involves the planning and timely modifying of instrument-tissue force interactions to allow for controlled deflections during the insertion in tissue. In this work, the effect of tip shape on these forces was studied using 10 mm diameter needle tips. Six different tips were selected, including beveled and conical versions, with or without pre-bend or pre-curve. A six-degree-of-freedom force/torque sensor measured the loads during indentations in tissue simulants. The increased insertion (axial) and bending (radial) forces with insertion depth - the force-displacement slopes - were analyzed. Results showed that the ratio between radial and axial forces was not always proportional. This means that the tip load does not have a constant orientation, as is often assumed in mechanics-based steering models. For all tip types, the tip-load assumed a more radial orientation with increased axial load. This effect was larger for straight tips than for pre-bent or pre-curved tips. In addition, the force-displacement slopes were consistently higher for (1) increased tip angles, and for (2) beveled tips compared to conical tips. Needles with a bent or curved tip allow for an increased bending force and a decreased variability of the tip load vector orientation.
منابع مشابه
Macroscopic and microscopic observations of needle insertion into gels.
Needle insertion into soft tissue is one of the most common medical interventions. This study provides macroscopic and microscopic observations of needle-gel interactions. A gelatin mixture is used as a soft-tissue simulant. For the macroscopic studies, system parameters, such as insertion velocity, needle diameter, gel elasticity, needle tip shape (including bevel angle) and insertion motion p...
متن کاملRobotic needle insertion: effects of friction and needle geometry
Two experiments were performed to determine the effects of friction and needle geometry during robotic needle insertion into soft tissues. In Experiment I, friction forces along the instrument axis were characterized during needle insertion into bovine liver under CT fluoroscopic imaging. Because the relative velocity of the tissue and needle affect viscous and Coulomb friction, the needle inse...
متن کاملEstimation of the friction force during the needle insertion using the disturbance observer and the recursive least square
Needle insertion can be performed with the aid of an ultrasound (US) image. Detecting the position of a needle in a US image requires considerable technical expertise. To detect whether the needle has reached the target, the physician usually relies on physically sensing the amount of force being fed back from the tip of the needle to their fingertip. The goal of our research was to develop a f...
متن کاملA Computational study on the effect of different design parameters on the accuracy of biopsy procedure
Needle insertion is a minimally invasive technique in diagnosing and treating tumors. However, to perform a surgery accurately, the tissue should have minimum amount of displacement during needle insertion so that it reaches the target tissue. Therefore, the tissue membrane has to move less to decrease rupturing under the membrane. In this study, the effect of different design parameters on dis...
متن کاملEffects of Rotational Motion in Robotic Needle Insertion
Background: Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations.Objective: In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploite...
متن کامل