Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice.

نویسندگان

  • Max C Wu
  • Dong-Wei Gao
  • Richard E Sievers
  • Randall J Lee
  • Bruce H Hasegawa
  • Michael W Dae
چکیده

OBJECTIVES Although transgenic mice have emerged as powerful experimental models of cardiovascular disease, methods for in vivo phenotypic assessment and characterization remain limited, motivating the development of new instruments for biologic measurement. BACKGROUND We have developed a single-photon emission computed tomography system with a pinhole collimator (pinhole SPECT) for high-resolution cardiovascular imaging of mice. In this study, we describe a protocol for myocardial perfusion imaging of mice using technetium-99m ((99m)Tc)-sestamibi and demonstrate the feasibility for measurement of perfusion defect size from pinhole SPECT images. METHODS Mice were anesthetized and injected with 370 MBq (10 mCi) of (99m)Tc-sestamibi. Tomographic projection images were acquired by rotating each mouse in a vertical axis in front of a stationary clinical scintillation camera equipped with a pinhole collimator. BALB/c mice (n = 15) were imaged after the permanent ligation of the left anterior descending coronary artery. The resulting defect size was measured from circumferential profiles of short-axis images. After imaging, the hearts were excised and sectioned to obtain ultra-high resolution digital autoradiographs of (99m)Tc-sestamibi, from which the actual infarct size was determined. RESULTS Reconstructed image quality was equivalent to that obtained for clinical myocardial perfusion imaging. Linear regression analysis produced a correlation coefficient of 0.83 (p < 0.001) between the measured and actual values of the defect size. CONCLUSIONS These results demonstrate that myocardial perfusion can be characterized qualitatively and quantitatively in mice using pinhole SPECT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Effects of depression on myocardial perfusion scintigraphy [Persian]

  Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...

متن کامل

A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...

متن کامل

Phase II Safety and Clinical Comparison With Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease

Objectives This was a phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for positron emission tomography (PET) myocardial perfusion imaging (MPI) with Tc-99m single-photon emission computed tomography (SPECT) MPI with regard to image quality, interpretative certainty, defect magnitude, and detection of coronary artery disease (CAD) ( 50% stenosis) on in...

متن کامل

Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report

Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, sit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2003