A frequency-domain analytical model of an uncontrolled single-phase voltage-source rectifier
نویسندگان
چکیده
The harmonic currents generated by the single-phase rectifier are well known. As the levels of these currents become larger, the use of power conditioners such as shunt active filters to lower the levels is becoming more attractive. In order to analyze the interaction between the condition, ac system, and rectifier it is necessary to have an accurate model of the rectifier. This paper describes a frequency-domain analytical model of the single-phase rectifier. The model includes the dominant frequency transfer mechanisms. These are the direct transfer and that due to the modulation of the switching instants. A small-signal linearized analysis is presented and the behavior predicted is confirmed by perturbation analysis using time-domain simulation. Accurate results are obtained, and the importance of including the switching instant modulation is shown.
منابع مشابه
A Novel Stand-Alone Single-Phase Induction Generator Using a Three-Phase Machine and a Single-Phase PWM Inverter
A new type of single-phase stand-alone induction generator using a three-phase induction machine and a single-phase voltage-source PWM inverter is introduced. The generator scheme is capable of producing constant load frequency with a very well regulated output voltage. A small lead acid battery and a single-phase full diode-bridge rectifier are used to feed the inverter. The inverter feeds one...
متن کاملA Probabilistic Three-Phase Time Domain Electric Arc Furnace Model based on analytical method
An electric arc furnace (EAF) is known as nonlinear and time variant load that causes power quality (PQ) problems such as, current, voltage and current harmonics, voltage flicker, frequency changes in power system. One of the most important problems to study the EAF behavior is the choice of a suitable model for this load. Hence, in this paper, a probabilistic three-phase model is proposed base...
متن کاملClosed-Form Analytical Investigation of Space-Vector PWM Inverter Fed Induction Motor Drive under DC-Bus Voltage Pulsation
Abstract-Voltage sag or unbalance conditions at the input rectifier stage of the ac-dc-ac rectifier-inverter induction motor drive can cause the significant amounts of harmonic voltage at twice the line frequency 2f1. This voltage ripple can have a degrading effect on the induction-machine performance characteristics. This paper presents an analytical closed-form mathematical model and analysis...
متن کاملDC Impedance-Model-Based Resonance Analysis of a VSC-HVDC System
Resonances can have negative impact on a Voltage Source Converter-High Voltage DC (VSC-HVDC) system. This paper develops dc impedance models for the rectifier and inverter stations for a VSC-HVDC system when they are viewed from a dc terminal. The impedance models take converter controllers into account. The derived impedance models are validated by comparing frequency responses of the analytic...
متن کاملPumped Storage Power Plant Control System Modeling by Applying VSI and Vector control principle
This paper includes modeling and simulation of 180 MW units of pumped storage power plant with Variable speed machines. In this method, voltage source inverters are used instead of traditional cyclo-converters. This paper aims to control the voltage source inverters and maintain DC voltage at a constant value. AC/ DC/ AC converter is used in system configuration structure in order to control an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE Trans. Industrial Electronics
دوره 47 شماره
صفحات -
تاریخ انتشار 2000