Patients' sera were analyzed for carbamazepine and ethosuximide by enzyme immunoassay (x) and gas chromatography (y), and the results were compared. The correlation coefficients were: for carbamazepine, x vs. y 0.94 (n = 93); for ethosuximide, x vs. y 0.99 (n = 30). These results suggest that the two methods could be used interchangeably. Ten serum samples supplemented with carbamazepine (2.5 to 12.5 mg/liter) and ethosuximide (20.0 to 130.0 mg/liter) were analyzed by both methods. The correlation coefficients were: x vs. y 0.99 (n = 10) for carbamazepine and x vs. y 0.99 (n =10) for ethosuximide.
منابع مشابه
Simultaneous rapid HPLC determination of anticonvulsant drugs in plasma and correlation with EMIT.
A method is presented for measuring simultaneously five anti-convulsants (primidone, ethosuximide, phenobarbital, carbamazepine and diphenylhydantoin) in serum and plasma by high-performance liquid chromatography (HPLC) using alphenal (5 - allyl - 5 - phenyl - barbituric acid) as the internal standard. All five drugs are separated from each other and, in the case of primidone, from its metaboli...
متن کاملMonitoring of therapeutic serum concentrations of antiepileptic drugs by a newly developed gas chromatographic procedure and enzyme immunoassay (EMIT): a comparative study.
A gas chromatographic procedure for the simultaneous determination of carbamazepine, phenobarbital and phenytoin using SP 2510 DA as stationary phase is presented. The antiepileptic drugs are determined simultaneously without derivatisation under isothermal conditions by a flame ionisation detector. The gas chromatographic procedure can be easily mechanized. The coefficient of variation for the...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 23 9 شماره
صفحات -
تاریخ انتشار 1977