Differential linear scan voltammetry: analytical performance in comparison with pulsed voltammetry techniques.

نویسندگان

  • Disha B Sheth
  • Miklós Gratzl
چکیده

We report here on differential linear scan voltammetry, DLSV, that combines the working principles of linear scan voltammetry, LSV, and the numerous existing pulsed voltammetry techniques. DLSV preserves the information from continuous interrogation in voltage and high accuracy that LSV provides about electrochemical processes, and the much better sensitivity of differential pulsed techniques. DLSV also minimizes the background current compared to both LSV and pulsed voltammetry. An early version of DLSV, derivative stationary electrode polarography, DSEP, had been proposed in the 1960s but soon abandoned in favor of the emerging differential pulsed techniques. Relative to DSEP, DLSV takes advantage of the flexibility of discrete smoothing differentiation that was not available to early investigators. Also, DSEP had been explored in pure solutions and with reversible electrochemical reactions. DLSV is tested in this work in more challenging experimental contexts: the measurement of oxygen with a carbon fiber microelectrode in buffer, and with a gold microdisc electrode exposed to a live biological preparation. This work compares the analytical performance of DLSV and square wave voltammetry, the most popular pulsed voltammetry technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...

متن کامل

Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...

متن کامل

Arsenic detection from water using a silver-modified carbon nanotubes composite electrode

In this study, the protocol for arsenic (III) detection from an aqueous solution using stripping voltammetry on a silver-modified synthetic zeolite-carbonnanotubes-epoxy composite electrode (CNT-AgSZ) was elaborated. Three types of electrochemical techniques were used in order to optimize the operating conditions, i.e., cyclic voltammetry, differential-pulsed voltammetry and squarewave voltamme...

متن کامل

Biomedical Application of a Novel Nanostructured-based Electrochemical Platform for Therapeutic Monitoring of an Antiepileptic Drug; Gabapentin

Herein, gold nanoparticle had been successfully synthesized through a simple, inexpensive and clean electrochemical technique. Gold nanoparticles were directly deposited on the electrode surface using an electrochemical strategy. Then, the electrochemical deposition parameters (such as applied potential and deposition time) were optimized. 1.1 V and 250 s were applied as the optimal electrodepo...

متن کامل

Electrochemical Approach for Determination of Tertahydrozoline HCl Using Gold nanoparticles Electrode

The electrochemical behavior of tetrahydrozoline (THZ) was explored by cyclic voltammetry and differential pulse voltammetry. A well-defined peak at 915 mV using gold nanomodified electrode (AuNPts/CP) in presence of sodium dodecyl sulphate (SDS) was detected. Different buffers, pH and scan rates on oxidation peak current were studied. Linear calibration curve was achieved in the range of 1.99×...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 405 16  شماره 

صفحات  -

تاریخ انتشار 2013