Calculation of depth dose profiles with a track structure code
نویسنده
چکیده
A prerequisite for applying high-LET radiation like protons or carbon ions to patients is the precise knowledge of absorbed dose, specifically the depth dose distribution. The legal restraints imposed by the authorities requires the Bragg peak position to be reproduced within 0.5 mm and the calculated absorbed dose distribution to agree within 5% (on average) with the measurements. These conditions are usually met by our treatment planning code TRiP98 [1, 3] and its builtin beam model [4]. This code uses semiempirical fragmentation cross sections and external energy loss tables to compute numerically the depth dose distributions. The question now arises whether microscopic Monte Carlo (MC) codes based on single interactions of ions and δ-electrons could reproduce depth dose distributions with similar accuracy. The answer is not obvious since ab-initio simulations would need very accurate primary interaction cross sections. To address this question an established heavy ion track structure MC code [5] was reworked (TRAX, [6]). In particular, the restriction to track segment conditions has been removed so that ion depth dose profiles can easily be calculated. In addition, other therapy-relevant quantities like ionization yields in dosimetric setups and possibly even W-values could be simulated on a very basic level. Total and differential elastic scattering cross sections for electrons were fitted to experimental data, as well as the excitation cross sections. Total electron ionization cross sections are calculated according to the relativistic model of Kim [7] with empirical corrections to match low-energy experimental data. Ion cross sections are contructed semi-empirically as well. The relativistic Kim model was modified for ions to obtain the total ionization cross section, whereas the energy differential δ-electron cross section was evaluated with Rudd’s formulae [8]. The angular distribution of δ-electrons was taken from the Binary Encounter Approximation. However, since depth dose distributions are one-dimensional projections and because the path of δelectrons in water is short compared with the ion penetration depth, the accuracy of the angular distribution plays only a minor role. In contrast to track segment calculations where excitations by ions are usually neglected, these processes have to be included here to obtain reasonable agreement with the established energy loss tables. Since there are no experimental or theoretical data available an empirical approach was chosen by resorting to the electron excitation cross sections with the same velocity. At first only exploratory calculations were performed, so nuclear fragmentation processes have not been considered, they will certainly be included in future simulations. A first criterion is the correctness of the energy loss curve compared with the conventional approach. Figure 1 shows the ion energy loss obtained by integrating the δ-electron spectra and adding the binding energy as well as the enFigure 1: Energy loss for C in H2O. Symbols: from TRiP98, solid line: from TRAX
منابع مشابه
Adding 166Ho data to VARSKIN2 code and dose calculation to human skin
Background: Skin cancer can be treated by various methods. Electron radiotherapy has been a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. Depth dose distribution of 166Ho using VARSKIN2 code is presented in this work. Material and Methods: Depth dose distribution of 166Ho was calculated, using VARSKIN2 code by adding...
متن کاملThe effect of electronic disequilibrium on the received dose by lung in small fields with photon beams: Measurements and Monte Carlo study
Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...
متن کاملCalculation of airkerma conversion factor to personal dose equivalent at various depths using the Monte Carlo Code GATE
Several studies have been done with the aim of improving the quality of the radiation protection measurement in radiology and nuclear medicine. Among different subjects which are capable to be considered in this area, the measurement of the operational quantities of protection against the radiation ,such as, personal dose equivalent ,HP(d), at different depths (d=0.07mm, 3mm, 10mm) is an impor...
متن کاملDepth dose calculation of Holmium-166 for different shape source by VARSKIN3 code
Introduction: Using beta emitter radionuclide is a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. The aim of this research is to evaluate the tissue response to beta rays of 166Ho and determine the feasibility of beta emitting radionuclide for treatment of skin cancers. Methods: In this...
متن کاملCalculation of gel dose after external radiation therapy using optical CT
In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...
متن کاملMonte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy
Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001