Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment
نویسندگان
چکیده
Fluoroscopic images suffer from multiple modes of image distortion. Therefore, the purpose of this study was to compare the effects of correction using a range of two-dimensional polynomials and a global approach. The primary measure of interest was the average error in the distances between four beads of an accuracy phantom, as measured using RSA. Secondary measures of interest were the root mean squared errors of the fit of the chosen polynomial to the grid of beads used for correction, and the errors in the corrected distances between the points of the grid in a second position. Based upon the two-dimensional measures, a polynomial of order three in the axis of correction and two in the perpendicular axis was preferred. However, based upon the RSA reconstruction, a polynomial of order three in the axis of correction and one in the perpendicular axis was preferred. The use of a calibration frame for these three-dimensional applications most likely tempers the effects of distortion. This study suggests that distortion correction should be validated for each of its applications with an independent "gold standard" phantom.
منابع مشابه
Anatomical image-based rigid registration between fluoroscopic X-ray and CT: methods comparison and experimental results
This paper describes a practical, whole system approach to rigid registration between preoperative CT and intraoperative X-rays obtained with a tracked C-arm and demonstrates its efficacy experimentally. Our approach is generic, targeted to orthopaedic surgery, and includes fluoroscopic X-ray calibration, image distortion correction, optical tracking, and 2D/3D image registration. For 2D/3D ima...
متن کاملDesign, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملInsertion of Central Airway Stents – Endoscopic Vs Fluoroscopic Guided Techniques
Introduction: Tracheal stents are deployed to attenuate intrinsic or extrinsic airway compression. They remain the gold standard for management of airway stenosis, especially when surgical resection is contraindicated. This study aimed to determine whether stent placement, by either fluoroscopic guidance or rigid bronchoscopy, resulted in improved procedural outcomes. Methods: We compared two t...
متن کاملA novel approach for distortion correction for X-ray image intensifiers.
Applications of X-ray image intensifiers in medical imaging, include the use of fluoroscopic projection images to generate three-dimensional tomographic reconstructions. Unfortunately, the inherent distortions on the acquired projections deteriorate the quality of the reconstructed tomograms. Distortion correction can be performed using algorithms that can be classified as global or local accor...
متن کاملThree-dimensional localization of cortical electrodes in deep brain stimulation surgery from intraoperative fluoroscopy
Electrophysiological recordings from subdural electrocorticography (ECoG) electrodes implanted temporarily during deep brain stimulation (DBS) surgeries offer a unique opportunity to record cortical activity for research purposes. The optimal utilization of this important research method relies on accurate and robust localization of ECoG electrodes, and intraoperative fluoroscopy is often the o...