Medial radio-carpal arthrodesis in three cats with a 2.0 mm locking maxillofacial plate system.
نویسندگان
چکیده
The medical records of three cats that were presented with severe carpal injury requiring radiocarpal arthrodesis were reviewed. Medial plating using the Compact 2.0 LOCK™ system was performed in all three cases. Although screw positioning may be difficult because of the large distance between the holes of the plate and the relatively large size of screws, plate loosening or metacarpal fractures did not occur. Long-term clinical and radiographic follow-up (6 months to 4.5 years) revealed excellent outcome in two cats. In the third cat, the radiocarpal joint did not undergo complete fusion. At four and a half years following surgery, recurrence of forelimb lameness was associated with breakage of the plate.
منابع مشابه
First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملSkeletal stability after mandibular setback surgery: bicortical fixation using a 2.0-mm locking plate system versus monocortical fixation using a nonlocking plate system.
PURPOSE This study was conducted to compare the time-course changes in condylar long-axis and skeletal stability after sagittal split ramus osteotomy (SSRO) with bicortical plate fixation versus monocortical plate fixation. PATIENTS AND METHODS Of a group of 40 Japanese patients diagnosed with mandibular prognathism, 20 underwent SSRO with bicortical plate fixation using a locking plate syste...
متن کاملBiomechanical comparison of a novel castless arthrodesis plate with T-plate and cross pin techniques for canine partial carpal arthrodesis.
OBJECTIVES To describe a novel canine castless partial carpal arthrodesis plate (par-CA) and its ex vivo biomechanical comparison with T-plate and cross pinning techniques for canine partial carpal arthrodesis. METHODS The three implant systems were applied to three cohorts of six forelimbs from Greyhounds euthanatized for reasons unrelated to the study. Intercarpal and carpometacarpal palmar...
متن کاملBilateral Pancarpal Arthrodesis in a German Shepherd Dog
Case Description- A 5-year old male German shepherd weighting 28 kg with the history of falling from the third floor 9 month previous was referred to the Small Animal Hospital. Clinical Findings- In clinical examination roughness and thickness of the skin of the palmar surface of both forelimbs were felt. The animal was using his palmar plane of both forelimbs to walk without any signs of pain ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary and comparative orthopaedics and traumatology : V.C.O.T
دوره 24 4 شماره
صفحات -
تاریخ انتشار 2011