Stylet angulation for routine endotracheal intubation with McGrath videolaryngoscope
نویسندگان
چکیده
BACKGROUND The McGrath videolaryngoscope (VL) provides excellent laryngoscopic views, but directing an endotracheal tube can be difficult, and thus the routine use of a stylet is recommended. The goal of this study is to determine the appropriate angle (60° vs 90°) of the stylet when using the McGrath VL by comparing the time to intubation (TTI). METHODS One hundred and forty patients aged 19 to 70 years (American Society of Anesthesiologists classification I or II) who required tracheal intubation for elective surgery were randomly allocated to 1 of 2 groups, at the 60° angle (n = 70) or the 90° angle (n = 70). Anesthesia was induced with propofol, fentanyl, and rocuronium. The primary outcome was TTI assessed by a blind observer. Glottic grade, use of optimal external laryngeal manipulation, failed intubation at first attempt, ease of intubation, and severity of oropharyngeal bleeding were also recorded. RESULTS The mean TTI was significantly shorter in the 60° group than in the 90° group (29.3 ± 6.4 vs 32.5 ± 9.4 s, P = 0.022). The glottic grade and degree of intubation difficulty were not significantly different between the 2 groups. CONCLUSIONS When intubating the patients with the McGrath videolaryngoscope, the 60° angled stylet allowed for faster orotracheal intubation than did the 90° angled stylet.
منابع مشابه
Intubation without use of stylet for McGrath videolaryngoscopy in patients with expected normal airway
BACKGROUND During McGrath videolaryngoscope (VL) intubation, a styletted endotracheal tube maintaining an upward distal tip angle is recommended by some manufacturers. However, a styletted endotracheal tube can elicit rare but potentially serious complications. The purpose of this study was to demonstrate that a nonstyletted tube with exaggerated curvature would be noninferior to a styletted tu...
متن کاملA comparison of the effectiveness of intubation using a McGrath Series 5 videolaryngoscope with either a Truflex articulating stylet or a standard intubation stylet in a group of medical students
Background. Intubation is the optimal method for opening the airway and effective ventilation of the patient. However, there are occasional problems with intubation, especially in patients with injuries under pre-hospital conditions. Therefore, it is important to identify devices, e.g., videolaryngoscopes or guides, which may facilitate and shorten the procedure. This study addresses the use of...
متن کاملA Comparison of Performance of Endotracheal Intubation Using the Levitan FPS Optical Stylet or Lary-Flex Videolaryngoscope in Morbidly Obese Patients
INTRODUCTION The use of videolaryngoscopes is recommended for morbidly obese patients. The aim of the study was to evaluate the Levitan FPS optical stylet (Levitan) vs Lafy-Flex videolaryngoscope (Lary-Flex) in a group of MO patients. METHODS Seventy-nine MO (BMI > 40 kg m(-2)) patients scheduled for bariatric surgery were included in the study and randomly allocated to the Levitan FPS or Lar...
متن کاملComparison of Tracheal Intubation Using the Storz’s C-Mac D-bladeTM Video-Laryngoscope Aided by TruflexTM Articulating Stylet and the PortexTM Intubating Stylet
BACKGROUND Tracheal intubation using Storz's C-Mac D-blade(TM) videolaryngoscope is associated with difficult negotiation of the tracheal tube into the glottis due to steep angulation of its blade. OBJECTIVES In this study, we hypothesized that Truflex(TM) articulating stylet with its ability to dynamically tailor the ETT shape to patients' oropharyngeal anatomy would be better suited to the ...
متن کاملAssessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
BACKGROUND A variety of videolaryngoscopes with angulated blade have been recently introduced into clinical practice. They provide an indirect view of the glottic structures in normal and challenging clinical settings. Despite the very good visualization of the laryngeal structures by these devices, the insertion and advancement of the endotracheal tube may be prolonged and occasionally fail as...