For single-fraction stereotactic radiosurgery (SRS) using linac in brain metastases, more accurate treatment delivery with higher tumor absorbed doses and lower absorbed doses to normal tissues remains an enormous challenge. The purpose of this study was to investigate the dosimetric superiority in flattening filter free beams (FFF) for volumetric modulated arc therapy (VMAT) in single brain metastasis. 68 patients with single brain metastasis were included in this study. Every patient was subjected to VMAT treatment plans using 6 MV standard flattened (FF) beams (VMAT_FF) and 6 MV FFF beams (VMAT_FFF) with single fraction doses of 20 Gy. Dosimetric evaluation was performed by analysis of target coverage, dose gradients, beam-on time (BOT), gantry speed and number of monitor units (MU). There were no differences between VMAT_FF and VMAT_FFF plans in conformity and MU. VMAT_FFF plans showed obvious superiority in homogeneity, dose gradients and efficiency. For the mean BOT, VMAT_FFF plans provided a significant decrease by 42.8% compared with VMAT_FF. By the use of FFF beams, brain irradiation was minimized with about 2% reductions in low-dose regions (about 5-10 Gy). FFF beams not only resulted in more efficiency by reducing treatment time, but also provided further brain sparing compared to traditional techniques for SRS in single brain metastasis.
منابع مشابه
Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode
Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...
متن کاملDosimetric impact of intra-fraction motion during high dose rate stereotactic vertebral radiotherapy using flattened and flattening filter free beams
Submitted Volumetric modulated arc therapy for stereotactic body radiotherapy: Planning considerations, delivery accuracy and efficiency
متن کاملDosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study
Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...
متن کاملDosimetric comparison of Helical Tomotherapy and Gamma Knife Stereotactic Radiosurgery for single brain metastasis
BACKGROUND Helical Tomotherapy (HT) integrates linear accelerator and computerized tomography (CT) technology to deliver IMRT. Targets are localized (i.e. outlined as gross tumor volume [GTV] and planning target volume [PTV]) on the planning kVCT study while daily MVCT is used for correction of patient's set-up and assessment of inter-fraction anatomy changes. Based on dosimetric comparisons, t...
متن کاملDosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma
Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...
متن کامل