Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption.

نویسندگان

  • C Durack
  • S Patel
  • J Davies
  • R Wilson
  • F Mannocci
چکیده

AIM To compare in an ex vivo model the ability of digital intraoral radiography and cone beam computed tomography (CBCT) to detect simulated external inflammatory root resorption lesions, and to investigate the effect of altering the degree of rotation of the CBCT scanners X-ray source and imaging detector on the ability to detect the same lesions. METHODOLOGY Small and large simulated external inflammatory resorption (EIR) lesions were created on the roots of 10 mandibular incisor teeth from three human mandibles. Small volume CBCT scans with 180° and 360° of X-ray source rotation and periapical radiographs, using a digital photostimulable phosphor plate system, were taken prior to and after the creation of the EIR lesions. The teeth were relocated in their original sockets during imaging. Receiver operator characteristic (ROC) analysis and kappa tests of the reproducibility of the imaging techniques were carried out and sensitivity, specificity, positive and negative predictive values (PPV and NPV) were also determined for each technique. RESULTS The overall area under the ROC curve (Az value) for intraoral radiography was 0.665, compared to Az values of 0.984 and 0.990 for 180° and 360° CBCT, respectively (P<0.001). The sensitivity and specificity of 180° and 360° CBCT were significantly better than intraoral radiography (P<0.001). CBCT, regardless of the degree of rotation, had superior NPVs (P<0.01) and PPVs (P<0.001) to periapical radiography. The intra- and inter-examiner agreement was significantly better for CBCT than it was for intraoral radiography (P<0.001). The ability of small volume CBCT to detect simulated EIR was the same regardless of whether 180° or 360° scans were taken. Examiners were significantly better able to identify the exact location of the artificial resorption lesions with CBCT than they were with periapical radiographs (P<0.001). CONCLUSION CBCT is a reliable and valid method of detecting simulated EIR and performs significantly better than intraoral periapical radiography. Small volume CBCT operating with 360° of rotation of the X-ray source and detector is no better at detecting small, artificially created EIR cavities than the same device operating with 180° of rotation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

PURPOSE The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. MATERIALS AND METHODS Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital ...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Detection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography.

AIM To compare the diagnostic accuracy of intraoral digital periapical radiography with that of cone beam computed tomography (CBCT) for the detection of artificial periapical bone defects in dry human jaws. METHODOLOGY Small and large artificial periapical lesions were prepared in the periapical region of the distal root of six molar teeth in human mandibles. Scans and radiographs were taken...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.&nbsp; Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2011