Radial Distribution Function of Liquid Sodium
نویسنده
چکیده
The radial distribution function of liquid sodium has been studied by considering the integral equation Perturbation Theory of Madden and Fitts for the reference part and the optimised cluster theory for the attractive part of the pair potential. Calculations were carried out for the long range oscillatory potential of Schiff. The calculated results are compared with the molecular dynamics calculations HTA, OCT and with experiment. The agreement was found to be satisfactory.
منابع مشابه
Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code
Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...
متن کاملDetermination of Optimal Capacity and Location of Distributed Generations in Radial Distribution Systems using Krill Herd Algorithm
Abstract Reliability and active power loss are two fundamental parameters in the design and planning of distribution systems that have always attracted the attention of power distribution systems designers and engineers. The improvement of reliability and the reduction of power loss are investigated as the primary objective functions and voltage profile as the secondary objective function. A me...
متن کاملInvestigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method.
Introduction: The commercial 252Cf sources are too large in size and clinical applications of neutron brachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, c...
متن کاملInvestigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method
Introduction:The commercial 252Cf sources are too large in size and clinical applications of neutronbrachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, cal...
متن کاملOptimal Reconfiguration and Capacitor Allocation in Radial Distribution Systems Using the Hybrid Shuffled Frog Leaping Algorithm in the Fuzzy Framework
In distribution systems, in order to diminish power losses and keep voltage profiles within acceptable limits, network reconfiguration and capacitor placement are commonly used. In this paper, the Hybrid Shuffled Frog Leaping Algorithm (HSFLA) is used to optimize balanced and unbalanced radial distribution systems by means of a network reconfiguration and capacitor placement. High accuracy and ...
متن کامل