Radial Distribution Function of Liquid Sodium

نویسنده

  • M. Rami
چکیده

The radial distribution function of liquid sodium has been studied by considering the integral equation Perturbation Theory of Madden and Fitts for the reference part and the optimised cluster theory for the attractive part of the pair potential. Calculations were carried out for the long range oscillatory potential of Schiff. The calculated results are compared with the molecular dynamics calculations HTA, OCT and with experiment. The agreement was found to be satisfactory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

متن کامل

Determination of Optimal Capacity and Location of Distributed Generations in Radial Distribution Systems using Krill Herd Algorithm

Abstract Reliability and active power loss are two fundamental parameters in the design and planning of distribution systems that have always attracted the attention of power distribution systems designers and engineers. The improvement of reliability and the reduction of power loss are investigated as the primary objective functions and voltage profile as the secondary objective function. A me...

متن کامل

Investigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method.

Introduction: The commercial 252Cf sources are too large in size and clinical applications of neutron brachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, c...

متن کامل

Investigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method

 Introduction:The commercial 252Cf sources are too large in size and clinical applications of neutronbrachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, cal...

متن کامل

Optimal Reconfiguration and Capacitor Allocation in Radial Distribution Systems Using the Hybrid Shuffled Frog Leaping Algorithm in the Fuzzy Framework

In distribution systems, in order to diminish power losses and keep voltage profiles within acceptable limits, network reconfiguration and capacitor placement are commonly used. In this paper, the Hybrid Shuffled Frog Leaping Algorithm (HSFLA) is used to optimize balanced and unbalanced radial distribution systems by means of a network reconfiguration and capacitor placement. High accuracy and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013