Autoconfocal microscopy with a cw laser and thermionic detection.

نویسندگان

  • Daryl Lim
  • Kengyeh K Chu
  • Jerome Mertz
چکیده

We introduce an application of thermionic emission in a PMT photocathode. Because of the nonlinear dependence of thermionic emission on absorbed laser power, a conventional PMT is found to produce a virtual pinhole effect that rejects unfocused light at least as strongly as a physical pinhole. This virtual pinhole effect is exploited in a scanning transmission confocal microscope equipped with a cw laser source. Because the area of the PMT photocathode is large, signal descanning is not required and thermionic detection acts as a self-aligned pinhole. Our technique of thermionic-detection autoconfocal microscopy is further implemented with graded-field contrast to obtain enhanced phase-gradient sensitivity in unlabeled samples, such as rat hippocampal brain slices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Limiting Properties of Colloids Enhanced by Gold Nanoparticles Based on Nonlinear Refraction for Cw Laser Illumination

In this work, thermo-optical properties of gold nanoparticle colloids are studied using continuous wave (CW) laser irradiation at 532 nm. The nanoparticle colloids are fabricated by 18 ns pulsed laser ablation of pure gold plate in the distilled water. The formation of the nanoparticles has been evidenced by optical absorption spectra and transmission electron microscopy. The nonlinear optical ...

متن کامل

Autoconfocal microscopy with nonlinear transmitted light detection

We describe a simple and robust technique for transmission confocal laser scanning microscopy wherein the detection pinhole is replaced by a thin second-harmonic generation crystal. The advantage of this technique is that self-aligned confocality is achieved without the need for signal descanning. We derive the point-spread function of our instrument and quantify both signal degradation and bac...

متن کامل

Use of laser-triggered gold nanoparticle-grafted dual light and temperature-responsive polymeric sensor for the recognition of thioguanine as anti-tumor agent

Objective(s): Today, there is an urgent need for improved sensor materials for drug sensing and effective monitoring and interventions in this area are highly required to struggle drug abuse. The present study aimed to synthesize a thioguanine-responsive sensor based on a nanocomposite consisting of AuNP-grafted light- and temperature-responsive poly butylmethacrylate-co-acrylamide-co-methacryl...

متن کامل

gSTED Microscopy with an OPSL: Cutting Edge Super-Resolution Breaking the diffraction limit with a CW OPSL

In order to probe cell biology at the molecular level and correlate single molecule activity with macroscopic cellular behavior in real-time, biologists need farfield microscopy techniques with the highest possible spatial as well as temporal resolution. Driven by this need, the use of lasers in confocal microscopy has taken fluorescence microscopy to the diffraction limit, which was long consi...

متن کامل

Effects of Electron-Gun and Laser Parameters on Collection Efficiency and Packet Duration in Ultrafast Electron Microscopy

Real-space imaging of full-morphological, angstrom-scale structural dynamics occurring on the femtosecond (fs) timescale is possible with ultrafast electron microscopy (UEM) via the stroboscopic pump-probe methodology enabled by interfacing an otherwise standard TEM with a short-pulsed laser system [1-3]. The technology has matured to the point that commercial systems, such as the FEI Tecnai Fe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 33 12  شماره 

صفحات  -

تاریخ انتشار 2008