00 2 A Calorimetric Search on Double Beta Decay of 130
نویسندگان
چکیده
We report on the final results of a series of experiments on double decay of Te carried out with an array of twenty cryogenic detectors. The set-up is made with crystals of TeO2 with a total mass of 6.8 kg, the largest operating one for a cryogenic experiment. Four crystals are made with isotopically enriched materials: two in Te and two others in Te . The remaining ones are made with natural tellurium, which contains 31.7 % and 33.8 % Te and Te , respectively. The array was run under a heavy shield in the Gran Sasso Underground Laboratory at a depth of about 3500 m.w.e. By recording the pulses of each detector in anticoincidence with the others a 90 % C.L. lower limit of 2.1 × 10 years has been obtained at the 90 % C.L. on the lifetime for neutrinoless double beta decay of Te . In terms of effective neutrino mass this is the most restrictive limit in direct experiments, after those obtained with Ge diodes. Limits on other lepton violating decays of Te and to the neutrinoless double beta decay of Te to the ground state of Xe are also reported and discussed. Possible evidence is presented for the two neutrino double beta decay of Te . Some consequences of the present results in the interpretation of geochemical experiments are discussed.
منابع مشابه
x / 02 11 07 1 v 3 2 5 Fe b 20 03 A Calorimetric Search on Double Beta Decay of 130
We report on the final results of a series of experiments on double beta decay of Te carried out with an array of twenty cryogenic detectors. The set-up is made with crystals of TeO2 with a total mass of 6.8 kg, the largest operating one for a cryogenic experiment. Four crystals are made with isotopically enriched materials: two in Te and two others in Te . The remaining ones are made with natu...
متن کاملJa n 20 03 A Calorimetric Search on Double Beta Decay of 130
We report on the final results of a series of experiments on double decay of Te carried out with an array of twenty cryogenic detectors. The set-up is made with crystals of TeO2 with a total mass of 6.8 kg, the largest operating one for a cryogenic experiment. Four crystals are made with isotopically enriched materials: two in Te and two others in Te . The remaining ones are made with natural t...
متن کامل0 30 10 07 v 2 8 A pr 2 00 3 A Search for various Double Beta Decay Modes of Cd , Te and Zn Isotopes
Various double beta decay modes of Cd, Zn and Te isotopes are explored with the help of CdTe and CdZnTe semiconductor detectors. The data set is splitted in an energy range below 1MeV having a statistics of 134.5 g·d and one above 1MeV resulting in 532 g·d. No signals were observed in all channels under investigation. New improved limits for the neutrinoless double beta decay of Zn of T1/2 > 1....
متن کامل2 v 1 3 D ec 2 00 4 Search for neutrinoless double beta decay with the NEMO - 3 detector : first results
The NEMO-3 detector, which has been operating in the Fréjus Underground Laboratory since February 2003, is devoted to searching for neutrinoless double beta decay (ββ0ν). The expected performance of the detector has been successfully achieved. Half-lives of the two neutrinos double beta decay (ββ2ν) have been measured for 150 Nd. After 265 days of data collection from February 2003 until March ...
متن کاملl - th / 9 81 00 72 v 1 2 7 O ct 1 99 8 Weak Magnetism in Two Neutrino Double Beta Decay ∗
We have extended the formalism for the two-neutrino double beta decay by including the weak-magnetism term, as well as other second-forbidden corrections. The weak magnetism diminishes the calculated half-lives in ∼ 10%, independently of the nuclear structure. Numerical computations were performed within the pn-QRPA, for 76 Ge, 128 T e and 130 T e nuclei. No one of the second-forbidden correcti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002