Noncontact Screening Methods for the Detection of Narrow Anterior Chamber Angles.

نویسندگان

  • Priya L Dabasia
  • David F Edgar
  • Ian E Murdoch
  • John G Lawrenson
چکیده

PURPOSE Comparing diagnostic accuracy of biomicroscope techniques (van Herick and Smith's tests, evaluating limbal and central anterior chamber depth, respectively) and advanced imaging (Visante OCT and Pentacam) for detection of gonioscopically narrow anterior chamber angles (ACAs). METHODS A total of 78 subjects with narrow or open ACAs underwent four index tests, performed on both eyes by examiners masked to other test results. Diagnostic performance was compared with gonioscopy, using International Society of Geographical and Epidemiological Ophthalmology (ISGEO) definition of primary angle closure and a classification based on clinical opinion of occludability. Data were analyzed using both the eye and the individual as unit of analysis. Sensitivity, specificity, and partial area under the receiver operating characteristic curve (AUROC) were generated. RESULTS Using the eye as the unit of analysis, the van Herick grading cutoff of 25% or less and ISGEO gonioscopic classification achieved 80% (confidence interval [CI] 65 to 89) sensitivity and 92% specificity (CI 80 to 97) for narrow angle detection, with specificity reaching 97% (CI 87 to 100) for a cutoff of less than or equal to 15%. Notably, with a gonioscopic classification based on clinical opinion of occludability, van Herick (≤25%) together with Smith's test (≤2.50 mm) detected 100% of narrow angle subjects. Of the three Pentacam parameters, anterior chamber volume achieved highest test sensitivity of 85% (CI 70 to 94) using the ISGEO definition. Visante OCT ACA had greatest partial AUROC at 90% specificity, also yielding sensitivity and specificity greater than 85% using the Youden-derived cutoff of less than or equal to 20.7°and ISGEO definition. CONCLUSIONS Van Herick test and Visante OCT ACA exhibited best discrimination between narrow and open angles both alone, and in combination. Van Herick test affords advantages over Visante OCT, showing potential for identifying individuals who may benefit from further gonioscopic assessment in a case-finding or screening setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Van Herick Technique for Screening for Occludable Angles in an African Population

The current gold standard for screening for angle closure and adopting universal approaches to prophylaxis is the assessment of the anterior chamber (AC) angle by gonioscopy, a technique that has substantial interobserver variability and relies on subjective assessment. Slit-lamp estimation of the peripheral anterior chamber depth (ACD) by the Van Herick technique is a noncontact approach for e...

متن کامل

Glaucoma anterior chamber morphometry based on optical Scheimpflug images.

PURPOSE To compare the performance of gonioscopy and noncontact morphometry with anterior chamber tomography (High Resolution Pentacam - HR) using optical Scheimpflug images in the evaluation of the anterior chamber angle (ACA). METHODS Transversal study. 112 eyes from 74 subjects evaluated at the Glaucoma Department, Fluminense Federal University, underwent gonioscopy and Pentacam HR. Using ...

متن کامل

Association of narrow angles with anterior chamber area and volume measured with anterior-segment optical coherence tomography.

OBJECTIVES To describe the measurement of anterior chamber area and anterior chamber volume by anterior-segment optical coherence tomography and to investigate the association of these parameters with the presence of narrow angles. METHODS This was a cross-sectional study of subjects aged at least 50 years without ophthalmic symptoms recruited from a community clinic. All participants underwe...

متن کامل

Changing Trends of Imaging in Angle Closure Evaluation

Primary angle closure glaucoma (PACG) is a significant cause of visual disability worldwide. It predominantly affects the Eastern and South Asian population of the world. Early detection of anatomically narrow angles is important, and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA). Gonioscopy has given way to modern day i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 6  شماره 

صفحات  -

تاریخ انتشار 2015