Use of an instrumented treadmill for real-time gait symmetry evaluation and feedback in normal and trans-tibial amputee subjects.
نویسندگان
چکیده
The purpose of this research was to evaluate a newly developed system for assessing and providing feedback of gait symmetry information in real time to subjects walking on a motorised treadmill (the CCF Treadmill). The advantages of the system are that it allows the rapid collection and comparison of temporal and kinetic parameters of gait for multiple successive strides, at a constant known speed, without forcing subjects to target their footsteps. Gait asymmetries of six normal (mean age 42.7 years) and six unilateral transtibial amputee subjects (mean age 41.7, and average 6.0 years using a prosthesis) were quantified. The amputee group was the reevaluated after receiving five minutes of training with each of three different types of real-time visual feedback (RTVF). Asymmetries in the measured parameters before feedback were 4.6 times greater in the amputee population than in the normal group, and were consistent with the finding of previous authors. Significant decreases in gait asymmetry were demonstrated for all forms of feedback after amputees received feedback training. Results, however, indicated that gait asymmetries for different variables are not necessarily related, and that more work needs to be done to identify those variables for which attaining a more symmetrical gait pattern is most beneficial. Further work also needs to be done to determine the long term effects of such RTVF training. The CCF Treadmill and RTVF were shown to be potentially useful tools both for defining rehabilitation targets and for quantifying patients' progress towards those goals.
منابع مشابه
اصلاح الگوی راه رفتن در قطع عضو زیر زانو از طریق بازخورد همزمان بصری
Objective: The present paper reports on program of work undertaken to evaluate the effect of real time visual feedback on kinematics of prosthetic gait. Methods: A total of 6 below-knee male amputees were included in the study. Each individual underwent three trials of self-selected speed treadmill walking, in which real time visual feedback was provided from forward, backward, and later...
متن کاملBelievable Visual Feedback in Motor Learning Using Occlusion-based Clipping in Video Mapping
Gait rehabilitation systems provide patients with guidance and feedback that assist them to better perform the rehabilitation tasks. Real-time feedback can guide users to correct their movements. Research has shown that the quality of feedback is crucial to enhance motor learning in physical rehabilitation. Common feedback systems based on virtual reality present interactive feedback in a monit...
متن کاملUse of visual and proprioceptive feedback to improve gait speed and spatiotemporal symmetry following chronic stroke: a case series.
BACKGROUND AND PURPOSE Persistent deficits in gait speed and spatiotemporal symmetry are prevalent following stroke and can limit the achievement of community mobility goals. Rehabilitation can improve gait speed, but has shown limited ability to improve spatiotemporal symmetry. The incorporation of combined visual and proprioceptive feedback regarding spatiotemporal symmetry has the potential ...
متن کاملA rehabilitation treadmill with software for providing real-time gait analysis and visual feedback.
BACKGROUND AND SIGNIFICANCE Standard gait analysis techniques can be cumbersome and time consuming. Subjects must walk at a set speed, place their feet squarely on one or more force plates, and data normally cannot be collected for successive strides. Temporal, kinetic, and kinematic information collected during formal gait analyses can also be obtained from subjects walking on a motorized trea...
متن کاملEvaluation of a Viscoelastic Ankle-Foot Prosthesis at Slow and Normal Walking Speeds on an Able-Bodied Subject
Objectives: This paper describes further improvement and preliminarily evaluation of a novel viscoelastic ankle-foot prosthesis prototype. The objective was to control the ankle hysteresis at slow and normal walking speeds. Methods: Inspired by the ankle biomechanics, in which the hysteresis differs based on the gait speeds, a manually damping control mechanism imbedded in the prosthesis for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Prosthetics and orthotics international
دوره 20 2 شماره
صفحات -
تاریخ انتشار 1996