Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference

نویسندگان

  • Tiago Bravo Ferreira
  • Joana Portelinha
چکیده

PURPOSE To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL implantation (Artiflex p-IOL) with a follow-up period of 3 years. A Pentacam HR imaging system was used to measure the distance from various points of the anterior edge of the Artiflex IOL to the endothelial surface of the cornea, which we called endothelial-IOL (E-IOL) distance, in 45 eyes. The E-IOL distances were assessed at 1, 3, 6, 12, 24, and 36 months. Corresponding correlations of central endothelial distance to temporal and nasal edges and center of the IOL anterior surface were tabulated. RESULTS Mean follow-up was 21.39±11.28 months. A statistically significant reduction of the E-IOL distance was observed over the follow-up period (P<0.05), with the mean annual reduction being 24.70 μm. A strong positive correlation between the E-IOL distance of the edges of the IOL and the central distance was observed (correlation coefficients nasal/central: month 1, 0.905; month 36, 0.806; temporal/central: month 1, 0.906; month 36, 0.806; P<0.001). Moderate negative correlations were found between the spherical equivalent power of the implanted IOL and the E-IOL distance (correlation coefficients -0.271 to -0.412, P>0.05). For an E-IOL distance of the IOL edge >1500 μm, the distance from the endothelium to the central point of the p-IOL optic should be a minimum of 1,700 μm to improve the safety profile for Artiflex p-IOL implantation and reduce the potential complication of accelerated endothelial cell loss. CONCLUSION After Artiflex IOL implantation, the mean annual reduction of the E-IOL distance was 25 μm. A negative correlation existed between the spherical equivalent power of the implanted IOL and the postoperative E-IOL distance. The minimum E-IOL distance from the center of the IOL to minimize the risk of endothelial cell loss was 1.7 mm. This distance, as is the 1.5 mm initially proposed by Baikoff, is a postoperative value. We cannot make that assumption for the preoperative evaluation, as the morphometry of the anterior chamber changes with the implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artisan iris-fixated toric phakic intraocular lens for the correction of high astigmatism after deep anterior lamellar keratoplasty.

We report the refractive correction of high astigmatism in one eye of a 23-year-old woman following deep anterior lamellar keratoplasty (DALK) using an Artisan iris-fixated, toric, phakic intraocular lens (IOL). One year after implantation, uncorrected and corrected distance visual acuities were both 20/25, refraction was -1.00 D cylinder, and the endothelial cell count was 1827 cells/mm(2). Ir...

متن کامل

Anterior chamber iris-fixated phakic intraocular lens for anisometropic amblyopia.

We report a child who had implantation of an iris-fixated Artisan phakic intraocular lens (IOL) to correct high unilateral myopia to support the therapy of anisometropic amblyopia. After IOL implantation, the patient continued occlusion therapy to further treat the amblyopic eye. One year postoperatively, the best corrected visual acuity in the amblyopic eye was 1.00 and binocular stereovision ...

متن کامل

Iris-fixated phakic intraocular lens implantation for correction of high myopia in microspherophakia.

We report the refractive correction of high myopia in a 23-year-old patient with idiopathic microspherophakia using iris-fixated phakic intraocular lenses (pIOLs) (Verisyse/Artisan). Four years after bilateral implantation, the uncorrected distance visual acuity was 20/25 with a correction of 20/20(-1) in both eyes. No intraoperative or postoperative complications occurred. Iris-fixated pIOLs a...

متن کامل

Prominent decrease of superior midperipheral endothelial cell density after iris-fixated phakic intraocular lens implantation.

PURPOSE To evaluate changes in endothelial cell density (ECD) in the corneal region after implantation of an iris-fixated phakic intraocular lens (PIOL). METHODS Forty-five eyes of 25 myopic patients implanted with Artisan iris-fixated PIOLs (Ophtec BV) and 30 eyes of 15 myopic controls were enrolled. Corneal ECD and the distance between endothelium and the PIOL optic were evaluated in five d...

متن کامل

Streptococcus mitis/oralis endophthalmitis management without phakic intraocular lens removal in patient with iris-fixated phakic intraocular lens implantation

BACKGROUND To report a case of Streptococcus mitis/oralis endophthalmitis management which had developed after complicated iris-fixated phakic intraocular (pIOL) lens implantation. CASE PRESENTATION A 23-year-old-woman received pIOL implantation followed secondary intraocular intervention to lower intraocular pressure. The patient presented with severe pain and decreased visual acuity and was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014