Assessment of turbulent viscous stress using ICOSA 4D Flow MRI for prediction of hemodynamic blood damage
نویسندگان
چکیده
Flow-induced blood damage plays an important role in determining the hemodynamic impact of abnormal blood flow, but quantifying of these effects, which are dominated by shear stresses in highly fluctuating turbulent flow, has not been feasible. This study evaluated the novel application of turbulence tensor measurements using simulated 4D Flow MRI data with six-directional velocity encoding for assessing hemodynamic stresses and corresponding blood damage index (BDI) in stenotic turbulent blood flow. The results showed that 4D Flow MRI underestimates the maximum principal shear stress of laminar viscous stress (PLVS), and overestimates the maximum principal shear stress of Reynolds stress (PRSS) with increasing voxel size. PLVS and PRSS were also overestimated by about 1.2 and 4.6 times at medium signal to noise ratio (SNR) = 20. In contrast, the square sum of the turbulent viscous shear stress (TVSS), which is used for blood damage index (BDI) estimation, was not severely affected by SNR and voxel size. The square sum of TVSS and the BDI at SNR >20 were underestimated by less than 1% and 10%, respectively. In conclusion, this study demonstrated the feasibility of 4D Flow MRI based quantification of TVSS and BDI which are closely linked to blood damage.
منابع مشابه
Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications
Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Vari...
متن کاملAssessment of turbulent flow effects on the vessel wall using four-dimensional flow MRI.
PURPOSE To explore the use of MR-estimated turbulence quantities for the assessment of turbulent flow effects on the vessel wall. METHODS Numerical velocity data for two patient-derived models was obtained using computational fluid dynamics (CFD) for two physiological flow rates. The four-dimensional (4D) Flow MRI measurements were simulated at three different spatial resolutions and used to ...
متن کاملImproved assessment of aortic 3D blood flow with combined k-t accelerated 3D CINE bSSFP & 4D flow MRI
Background To determine hemodynamic parameters from 4D flow MRI, vessel boundaries are typically depicted by calculating a 3D phase contrast MR angiogram (PC-MRA) from 4D flow magnitude and flow images. However, this approach is limited by 1) low blood-tissue contrast of the magnitude images and 2) velocity weighting of PC-MRA may not fully depict areas of slow or swirling (vortex) flow. As a r...
متن کاملFour-dimensional flow assessment of pulmonary artery flow and wall shear stress in adult pulmonary arterial hypertension: results from two institutions.
PURPOSE To compare pulmonary artery flow using Cartesian and radially sampled four-dimensional flow-sensitive (4D flow) MRI at two institutions. METHODS Nineteen healthy subjects and 17 pulmonary arterial hypertension (PAH) subjects underwent a Cartesian 4D flow acquisition (institution 1) or a three-dimensional radial acquisition (institution 2). The diameter, peak systolic velocity (Vmax), ...
متن کاملAssessment of left ventricular hemodynamic forces in healthy subjects and patients with dilated cardiomyopathy using 4D flow MRI.
We hypothesized that the direction of global left ventricular (LV) hemodynamic forces during diastolic filling are concordant with the main flow axes in normal LVs, but that this pattern would be altered in dilated and dysfunctional LVs. Therefore, we aimed to assess the LV hemodynamic filling forces in a group of healthy subjects and compare them to the results from a group of patients with di...
متن کامل