Use of lyophilized calibrant plasmas for simplified international normalized ratio determination with a human tissue factor thromboplastin reagent derived from cultured human cells.
نویسندگان
چکیده
BACKGROUND For monitoring of treatment with oral anticoagulants, the clotting time obtained in the prothrombin time (PT) test is transformed to the International Normalized Ratio (INR) with use of a system-specific International Sensitivity Index (ISI). The calibrant plasma procedure (CPP) is an alternative approach to INR calculation based on the use of a set of lyophilized plasmas with assigned INRs. METHODS With the CPP, a linear relationship is established between log(PT) and log(INR), using orthogonal regression. CPP was validated for Simplastin HTF, a new human tissue factor reagent derived from cultured human cells. CPP precision was assessed as the CV of the slope of the regression line. The accuracy of the CPP was determined by comparing the INR obtained with the CPP with that obtained with the established ISI-based reference method. INRs of the calibrants were assigned by different routes: by manufacturer (consensus labeling) or by use of Simplastin HTF or International Reference Preparations (IRPs; rTF/95 or RBT/90). RESULTS The mean CV of the CPP regression slope ranged from 1.0% (Simplastin HTF reagent-specific INR) to 2.4% (INR assigned with rTF/95). INRs calculated with the CPP were similar to those obtained with the reference method, but when the routes for assigning INRs to the calibrant plasmas were compared, the mean difference in INR between CPP and the reference method was smaller with Simplastin HTF reagent-specific values. In several (but not all) cases, this difference was significant (P <0.05, t-test). CONCLUSION CPP can be used for local INR determination, but better precision and accuracy are obtained with reagent-specific INRs compared with INR assignment by consensus labeling or IRP.
منابع مشابه
Simplified method for international normalized ratio (INR) derivation based on the prothrombin time/INR line: an international study.
BACKGROUND The need to perform local International Sensitivity Index (ISI) calibrations and in particular the requirement for a manual method for prothrombin time (PT) determination, have proved to be obstacles to application of the WHO scheme for PT standardization. METHODS We used international normalized ratio (INR) derived with a set of only 5 European Concerted Action on Anticoagulation ...
متن کاملField study of lyophilised plasmas for local prothrombin time calibration in The Netherlands.
AIM To assess the effect of a lyophilised calibrant plasma procedure on the international normalised ratio (INR) and its interlaboratory variation. METHODS INR equivalent values were assigned to five lyophilised plasmas (one from normal donors and four from coumarin treated patients) by a reference laboratory using three calibrated thromboplastin reagents. The calibrant plasmas and five artif...
متن کاملGuidelines on preparation, certification, and use of certified plasmas for ISI calibration and INR determination--a rebuttal.
Reliable international normalized ratio (INR) determination depends on accurate values for international sensitivity index (ISI) and mean normal prothrombin time (MNPT). Local ISI calibration can be performed to obtain reliable INR. Alternatively, the laboratory may determine INR directly from a line relating local log(prothrombin time [PT]) to log(INR). This can be done by means of lyophilized...
متن کاملCalculation of System International Sensitivity Index: how many calibrant plasmas are required?
AIMS To determine the minimum number of calibrant plasmas required to assign an accurate System International Sensitivity Index (ISI). METHODS Eighteen lyophilised adsorbed and eight frozen coumarin plasmas were despatched to 57 participating laboratories. Each centre determined the prothrombin time of all of the plasmas using their routine system of coagulometer and thromboplastin reagent an...
متن کاملEvaluation of European Concerted Action on Anticoagulation lyophilized plasmas for INR derivation using the PT/INR line.
The prothrombin time/international normalized ratio (PT/INR) Line method based on 5 certified European Concerted Action on Anticoagulation (ECAA) plasmas provides reliable local INR values without conventional World Health Organization international sensitivity index calibrations. The present study investigated the use of different numbers and types of ECAA calibrant plasmas to derive accurate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 49 12 شماره
صفحات -
تاریخ انتشار 2003