A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.

نویسندگان

  • H Sakoda
  • A M Voice
  • H M McEwen
  • G H Isaac
  • C Hardaker
  • B M Wroblewski
  • J Fisher
چکیده

Cross-linked polyethylenes are being introduced widely in acetabular cups in hip prostheses as a strategy to reduce the incidence of wear debris-induced osteolysis. It will be many years before substantial clinical data can be collected on the wear of these new materials. Silane cross-linked polyethylene (XLPE) was introduced into clinical practice in a limited series of acetabular cups in 1986 articulating against 22.225-mm alumina ceramic femoral heads and showed reduced wear rates compared with conventionally sterilized (gamma irradiation in air) ultra-high molecular weight polyethylene (UHMWPE). We compared the wear of XLPE manufactured in 1986 with the wear of UHMWPE manufactured in 1986 in nonirradiated and irradiated forms. In the nonirradiated forms, the wear of XLPE was 3 times less than UHWMPE when articulating against smooth counterfaces. The nonirradiated materials did not show signs of oxidation. In the irradiated forms, only UHMWPE showed high levels of oxidation, and this caused a substantial increase in wear. Antioxidants added to XLPE during processing gave resistance to oxidative degradation. When sliding against scratched counterfaces, the wear of UHMWPE increased by a factor of 2 to 3 times. Against the same scratched counterfaces, the wear of XLPE increased dramatically by 30 to 200 times. This difference may be attributed to the reduction in toughness of XLPE. Clinically, XLPE has been articulated against damage-resistant ceramic heads, and this probably has been an important factor in contributing to reduced wear. New cross-linked polyethylenes differ considerably from XLPE. This study indicates that it is prudent to examine the wear of new polyethylenes under a range of conditions that may occur in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization and quantification of the cross-linking of linear low density polyethylene with silane grafting by Fourier transform infrared (FTIR) spectroscopy

The way of making cross-linkable polyethylene through silane grafting has gained much attention in recentyears because of its various advantages such as easy processing, low cost and capital investment andfavorable properties in the processed materials. This work deals with silane grafting and moisture crosslinkingof linear low density polyethylene (LLDPE). The grafting reaction was performed i...

متن کامل

Comparison of cross-linked polyethylene materials for orthopaedic applications.

Cross-linked polyethylenes are being marketed by orthopaedic manufacturers to address the problem of osteolysis caused by polyethylene particulate wear debris. Wear testing of these cross-linked polyethylenes in hip simulators has shown dramatic reduction in wear rate compared with standard ultrahigh molecular weight polyethylene, either gamma irradiated in air or nitrogen - or ethylene oxide-s...

متن کامل

Investigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation

The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR  is Ultra High Molecular Weight Polyethylene (UHMWPE). Pr...

متن کامل

Micro X-Ray Computed Tomography Mass Loss Assessment of Different UHMWPE: A Hip Joint Simulator Study on Standard vs. Cross-Linked Polyethylene

More than 60.000 hip arthroplasty are performed every year in Italy. Although Ultra-High-Molecular-Weight-Polyethylene remains the most used material as acetabular cup, wear of this material induces over time in vivo a foreign-body response and consequently osteolysis, pain, and the need of implant revision. Furthermore, oxidative wear of the polyethylene provoke several and severe failures. To...

متن کامل

Knee Simulator Wear of Cross-linked Uhmwpe with Normal and Mal-rotation Kinematics

Introduction: Wear of ultra-high molecular weight polyethylene (UHMWPE) is a major factor that affects longevity of the total joint replacement. In total hips (THR), cross-linking of polyethylene has been shown to be highly effective in reducing wear both clinically and experimentally [1-3]. Also, in TKR, Schmidig et al. [4] showed a 90% reduction of wear rate in 10 Mrad compared to 3 Mrad tibi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 17 8  شماره 

صفحات  -

تاریخ انتشار 2001