A standardized protocol for needle placement in suboccipital muscles.

نویسندگان

  • Richard C Hallgren
  • Michael T Andary
  • Andrew J Wyman
  • Jacob J Rowan
چکیده

The objective of this study was to assess the safety and accuracy of using common anatomic landmarks to guide the placement of needle electrodes into suboccipital muscles. Atrophic changes in suboccipital muscles have been reported in some patients who have tension-type headaches, and in some patients who have headaches resulting from whiplash-type injuries. These atrophic changes most likely result from disuse or denervation. Needle electromyography is a definitive technique for determining the cause of muscle atrophy, but requires that needle electrodes be inserted into the muscle. Suboccipital muscles present a challenge to the electromyographer in that they are physically small and are located in close proximity to one another. Atrophied muscles with fatty replacement and the presence of critical structures such as the vertebral artery further complicate the procedure. Using a standardized protocol, three investigators attempted blind needle insertions into each of the suboccipital muscles of eight embalmed cadavers. A dissector then assessed targeted muscle penetrations, final resting positions of the wires, and their proximity to critical structures. Eighty-one percent of 181 attempted insertions penetrated the targeted muscles: 83% for the rectus capitis posterior minor, 83% for the rectus capitis posterior major, 94% for the obliquus capitis superior, and 63% for the obliquus capitis inferior muscles, respectively. It was concluded that readily palpable external landmarks can be used to safely and reliably guide the insertion of needle electrodes into three of the four pairs of suboccipital muscles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Needle Placement in Cadavers: Non-Guided Versus Ultrasound-Guided

OBJECTIVE To compare the accuracy rates of non-guided vs. ultrasound-guided needle placement in four lower limb muscles (tibialis posterior, peroneus longus, and short and long heads of the biceps femoris). METHODS Two electromyographers examined the four muscles in each of eight lower limbs from four fresh frozen cadavers. Each electromyographer injected an assigned dye into each targeted mu...

متن کامل

Fibre types of human suboccipital muscles

Understanding the functional role of the cervical muscles is important for the effective diagnosis and treatment of cervical disorders. The suboccipital muscles are targets for treatment in whiplash and chronic headache, although their function remains unclear. There are no data on suboccipital muscle fiber type composition to facilitate an understanding of their function. Suboccipital muscles ...

متن کامل

Accuracy of botulinum toxin type A injection into the forearm muscles of chronic stroke patients with spastic flexed wrist and clenched fist: manual needle placement evaluated using ultrasonography.

OBJECTIVE To investigate the accuracy of manual needle placement for injection of botulinum toxin type A into the forearm muscles of adults with spastic flexed wrist and clenched fist as a consequence of stroke. DESIGN Prospective clinical study. PATIENTS A total of 41 adults with chronic stroke who were scheduled to receive botulinum toxin type A injection into the following forearm muscle...

متن کامل

The second terminations of the suboccipital muscles: An assistant pivot for the To Be Named Ligament

In the last two decades, many studies have focused on the muscles and dense connective tissues located in the suboccipital region. Our study investigated the existence of the second terminations originating from the suboccipital muscles, and the relationship between the variable types of the To Be Named Ligament (TBNL). Anatomical dissection was performed on 35 head-neck specimens. The existenc...

متن کامل

Can botulinum toxin type A injection technique influence the clinical outcome of patients with post-stroke upper limb spasticity? A randomized controlled trial comparing manual needle placement and ultrasound-guided injection techniques.

BACKGROUND Botulinum toxin type A is a first-line treatment for post-stroke focal spasticity, and the accuracy in delivering the toxin to the target muscles may influence the treatment outcome. Our aim was to compare the reduction of spasticity and the related finger position at rest improvement in post-stroke patients treated with botulinum toxin type A in upper limb muscles using ultrasound g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical anatomy

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 2008