Clinical evaluation of new heart valve prostheses: update of objective performance criteria.
نویسندگان
چکیده
This article summarizes the long-term clinical results of the Food and Drug Administration-approved heart valves, provides current updates to the objective performance criteria (OPC) used to evaluate new heart valve prostheses, and documents the steps that the International Organization for Standardization Committee used to arrive at the updated OPC. Data were extracted from 19 Food and Drug Administration summaries of safety and effectiveness data reports (31 series) and 56 literature articles (85 series) published from 1999 to 2012. The OPC were calculated for five valve-related complications by valve type (mechanical and bioprosthetic) and valve position (aortic and mitral).
منابع مشابه
Update of the European standards for inactive surgical implants in the area of heart valve prostheses.
OBJECTIVE The approval of a heart valve for the European market takes place in accordance with European and international standards. A new version of the EN Standards was published in June 2006, which responded to different technical innovations in the area of heart valve technology. This work outlines the differences between the new EN ISO 5840 (2005) and the old EN 12006-1 (1999). METHODS W...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملTotal Elbow Replacement in Dogs
Key Points Unlike previous and newer elbow prostheses, the TATE is a cementless, resurfacing press-fit design implanted as a single unit via limited surgical approaches. Subjective evaluation suggests that long term functional recovery and severe complication rates compare favorably to those of stemmed cemented designs. Prospective experimental and clinical evaluations as well as retrieva...
متن کاملTen year clinical evaluation of Starr-Edwards 2400 and 1260 aortic valve prostheses.
The long term performance characteristics of the 2400 and 1260 series of Starr-Edwards aortic prostheses were investigated by a follow up study of clinical outcome of 327 patients discharged from hospital with isolated aortic valve replacement. Follow up lasted for up to 10 years and was based on 1616 patient-years. The 2400 series cloth covered tracked valve was implanted in 182 patients from ...
متن کاملEvaluation of the marker of hypercoagulability prothrombin fragment F 1+2 in patients with mechanical or biological heart valve prostheses.
OBJECTIVE To investigate whether patients with heart valve prostheses and similar International Normalized Ratios (INR) have the same level of protection against thromboembolic events, that is, whether the anticoagulation intensity is related to the intensity of hypercoagulability suppression. METHODS INR and plasma levels of prothrombin fragment 1+2 (F1+2) were assessed in blood samples of 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of thoracic surgery
دوره 98 5 شماره
صفحات -
تاریخ انتشار 2014