Use of various common isolation media to evaluate the new VITEK 2 colorimetric GN Card for identification of Burkholderia pseudomallei.
نویسندگان
چکیده
The use of automated systems in the modern microbiology laboratory is becoming commonplace as the pressure of cost containment impacts on staff resources. With increased international travel and threats of bioterrorism, recognition and accurate identification of organisms such as Burkholderia pseudomallei is important. In areas where this organism is endemic, identification is not usually problematic. This study evaluates the performance of the new VITEK 2 colorimetric GN card for the identification of this organism. A total of 103 previously identified clinical isolates were tested with the new card with isolates taken from MacConkey agar, Columbia horse blood agar, Columbia sheep blood agar, and Trypticase soy agar in order to determine identification performance and to see if there was any variability in results due to the agar. Columbia horse blood agar produced the highest rates of identification (81%), followed by Trypticase soy agar (78%), Columbia sheep blood agar (75%), and MacConkey agar (63%). There was considerable variability in some of the reactions obtained. Seven isolates failed to identify from any of the agars used. This study highlights issues with the identification of this organism with the new VITEK 2 GN card. Enhancements of the algorithm parameters for the GN card are warranted and are in progress. Laboratory personnel need to be aware of the current limitations with this GN card and the software (version 4.02 or older for the VITEK 2 60/XL and version 1.02 or older for VITEK 2 Compact) and rely on clinical history, a high index of suspicion, and basic microbiology tests to confirm the identification of this organism.
منابع مشابه
Influence of Biochemical Features of Burkholderia pseudomallei Strains on Identification Reliability by Vitek 2 System
Background Burkholderia pseudomallei is a Gram-negative saprophytic soil bacterium that causes melioidosis, a potentially fatal disease endemic in wet tropical areas. The currently available biochemical identification systems can misidentify some strains of B. pseudomallei. The aim of the present study was to identify the biochemical features of B. pseudomallei, which can affect its correct ide...
متن کاملEvaluation of new colorimetric vitek 2 yeast identification card by use of different source media.
The new colorimetric Vitek 2 YST card was evaluated for identification of yeasts (136 strains) with respect to the influence of different source media. The Vitek 2 YST card achieved satisfactory results for all yeast species tested, with the exception of Candida guilliermondii, Candida norvegensis, Candida parapsilosis, Candida rugosa, and Candida tropicalis. After simple additional tests, 93.7...
متن کاملNew Vitek 2 colorimetric GN Card for identification of gram-negative nonfermentative bacilli.
The recent publication of Zbinden et al. (4) regarding the Vitek 2 colorimetric GN card for the identification of gramnegative nonfermentative bacilli contains data inconsistencies which the authors should have addressed before making recommendations for the use of this product. The authors stated that the 90 isolates tested were “well identified” but that 20/90 (22.2%) were not identified to t...
متن کاملReliability of automated biochemical identification of Burkholderia pseudomallei is regionally dependent.
Misidentifications of Burkholderia pseudomallei as Burkholderia cepacia by Vitek 2 have occurred. Multidimensional scaling ordination of biochemical profiles of 217 Malaysian and Australian B. pseudomallei isolates found clustering of misidentified B. pseudomallei isolates from Malaysian Borneo. Specificity of B. pseudomallei identification in Vitek 2 and potentially other automated identificat...
متن کاملComparative study of the new colorimetric VITEK 2 yeast identification card versus the older fluorometric card and of CHROMagar Candida as a source medium with the new card.
The new VITEK 2 colorimetric card was compared to the previous fluorometric card for identification of yeast. API 20C was considered the "gold standard." The new card consistently performed better than the older card. Isolates from CHROMagar Candida plates were identified equally as well as those from Sabouraud dextrose agar.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2006