GTNEUT: A code for the calculation of neutral particle transport in plasmas based on the Transmission and Escape Probability method
نویسنده
چکیده
GTNEUT is a two-dimensional code for the calculation of the transport of neutral particles in fusion plasmas. It is based on the Transmission and Escape Probabilities (TEP) method and can be considered a computationally efficient alternative to traditional Monte Carlo methods. The code has been benchmarked extensively against Monte Carlo and has been used to model the distribution of neutrals in fusion experiments.
منابع مشابه
An interface current balance formulation of neutral atom transport theory in plasmas
An interface current balance ~ICB! method for neutral particle transport is presented and specialized to the calculation of neutral atom transport in background plasmas. A multigroup extension of the ICB methodology is presented which enables the direct calculation of neutral atom energy distributions and energy and momentum transport, as well as particle transport. Extension of the ICB methodo...
متن کاملImprovements in the 2D TEP Neutral Particle Transport Calculation in Edge Plasmas
Extensions of the 2D Transmission and Escape Probability neutral particle transport method in treating the spatial non-uniformity of collision sources and neutral energy effects are presented. These extensions have been tested by benchmarks against Monte Carlo calculations for specially designed models and for realistic DIII-D discharges. The comparisons indicate these extensions improve accura...
متن کاملElectronic Transmission Wave Function of Disordered Graphene by Direct Method and Green's Function Method
We describe how to obtain electronic transport properties of disordered graphene, including the tight binding model and nearest neighbor hopping. We present a new method for computing, electronic transport wave function and Greens function of the disordered Graphene. In this method, based on the small rectangular approximation, break up the potential barriers in to small parts. Then using the f...
متن کاملA method for range calculation of proton in liquid water: Validation study using Monte Carlo method and NIST data
Introduction: The main advantage of using ion beams over photons in radiotherapy is due to their inverse depth-dose profiles, allowing higher doses to tumors, while better sparing normal tissues. When calculating dose distributions with ion beams, one crucial point is the uncertainty of the Bragg-peak range. Recently great effort is devoted to enhance the accuracy of the comput...
متن کاملThe Effects Of Interfacial Roughness On The Argon Ion Implanted Tantalum Films
In the present study, effect of interfacial roughness on the ion implanted Tantalum based surfaces has been investigated. The argon ions with energy of 30 keV and in doses of 1×1017 , 3×1017 , 5×1017 , 7×1017 , and 10×1017 (ion/cm2) have been used at ambient temperature. The Atomic Force Microscopy (AFM), analysis have been used to study and characterize the surfaces morphology. The effect of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer Physics Communications
دوره 161 شماره
صفحات -
تاریخ انتشار 2004