On optimal liver T2* measurement: region of interest or pixel-wise?

نویسندگان

  • Yanqiu Feng
  • Peter D Gatehouse
  • Peiguo Liu
  • John-Paul Carpenter
  • Dudley J Pennell
  • David N Firmin
  • Wufan Chen
  • Taigang He
چکیده

Background MRI T2* measurement is playing an important role in liver iron quantification. There are currently two clinical approaches measuring T2* in the region of interest ( ROI): the first is to fit the means of signals in the ROI (mean-ROI fitting, MRF) and the second to average the pixel-wisely fitted (PWF) T2*s in the ROI. In a recent study, Marro et al [1] compared the performances of PWF and MRF through mathematical simulations but only the offset model was evaluated. The purpose is to determines the optimal liver T2* measurement by evaluating the performances of MRF and PWF with 4 different fitting models on simulation and phantom data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Liver Iron Load Assessment by Pixel-Based T2* MRI in Thalassemic Patients

Purpose: To improve liver iron load assessment by investigating the precision of different approaches of T2 Measurement. Background: Iron overload is a major problem in the treatment of thalassemic patients. Liver iron concentration (LIC) is an important index toward the management of body iron load. The accuracy of iron load estimation may suffer from the methodology of T2 measurement and ther...

متن کامل

Myocardial T2* mapping: influence of noise on accuracy and precision

BACKGROUND Pixel-wise, parametric T2* mapping is emerging as a means of automatic measurement of iron content in tissues. It enables quick, intuitive interpretation and provides the potential benefit of spatial context between tissues. However, pixel-wise mapping uses much lower SNR data to estimate T2* when compared to region-based mapping thereby decreasing both its accuracy and precision. In...

متن کامل

Novel MRI T2 Mapping for Improved Myocardial Tissue Characterisation

Introduction: As part of our work on myocardial iron quantification we have developed an breath-hold fast spin echo (FSE) T2 technique with good reproducibility (1,2). This T2 technique, however, is based on region-ofinterest (ROI) analysis. Although ROI analysis can increase signal to noise ratio (SNR), it may introduce errors to T2 measurement by averaging every pixel within the region. By co...

متن کامل

Impact of region of interest size and location in Gafchromic film dosimetry

Introduction: Accurate film dosimetry requires careful consideration of sources of uncertainty. Some of the sources of uncertainty are dependent on the size and location of region of interest (ROI), especially in small fields. Avoiding the penumbra is often a reason for using a small ROI. In contrast, choosing very small ROIs may increase uncertainty due to the reduction of th...

متن کامل

Comparison of the region-based and pixel-wise methods for cardiac T2* analysis in 50 transfusion-dependent Thai thalassemia patients.

PURPOSE To compare the observer variability of the conventional region-based (RB) to the typical and proposed pixel-wise (PW) methods for cardiac T2* analysis in thalassemia patients. DESIGN AND METHODS Fifty thalassemia major patients were enrolled for the study. Short-axis bright- and black-blood sequences were acquired and analyzed using the RB and PW methods. Regions were defined using th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012