Continuous speech recognition in MR imaging reporting: advantages, disadvantages, and impact.
نویسندگان
چکیده
OBJECTIVE Our objective was to describe our experience with a commercially available continuous speech recognition system, highlighting the advantages, disadvantages, and costs compared with those of conventional transcription for MR imaging reports. MATERIALS AND METHODS Data from 5072 reports generated in our MR imaging section during a 9-month period after the implementation of a commercial continuous speech recognition system were compared with 4552 reports produced during the same period 1 year earlier. Information pertaining to the use of continuous speech recognition, report turnaround time, word recognition rate, report appearance, and equipment costs was collected. RESULTS After its system installation, continuous speech recognition was used to dictate 81.8% of all reports. The mean report turnaround time decreased from 87.8 to 43.6 hr, and report availability at 24 hr increased from 10.5% to 62.5%. The system was found to have an average word recognition accuracy of 92.7% for spontaneous dictation. Mean report length declined from 95 to 60 words, with an increase in spacing errors from 0.3 to 8.0 per 1000 words and a decrease in spelling errors from 3.0 to 0.8 per 1000 words. Initial hardware and software costs were approximately $10,000, compared with a yearly cost of $12,000 for human transcription. CONCLUSION Although the technology is still evolving and was evaluated in its earliest implementation stages, continuous speech recognition nonetheless markedly improved report turnaround time and proved cost-effective.
منابع مشابه
Speaker Adaptation in Continuous Speech Recognition Using MLLR-Based MAP Estimation
A variety of methods are used for speaker adaptation in speech recognition. In some techniques, such as MAP estimation, only the models with available training data are updated. Hence, large amounts of training data are required in order to have significant recognition improvements. In some others, such as MLLR, where several general transformations are applied to model clusters, the results ar...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملSpeaker Adaptation in Continuous Speech Recognition Using MLLR-Based MAP Estimation
A variety of methods are used for speaker adaptation in speech recognition. In some techniques, such as MAP estimation, only the models with available training data are updated. Hence, large amounts of training data are required in order to have significant recognition improvements. In some others, such as MLLR, where several general transformations are applied to model clusters, the results ar...
متن کاملبه کارگیری سامانه تبدیل گفتار به متن در حوزه مراقبت سلامت: مزایا، محدودیتها، راهکارها
Background and Aim: The applicability of any technology to enter a certain field is determined by defining the advantages and disadvantages of the system in that field. The aim of this study is to show the advantages and limitations of using speech recognition systems in health care and providing practical solutions to improve the acceptability of the system in that field. Materials and M...
متن کاملImproved Bayesian Training for Context-Dependent Modeling in Continuous Persian Speech Recognition
Context-dependent modeling is a widely used technique for better phone modeling in continuous speech recognition. While different types of context-dependent models have been used, triphones have been known as the most effective ones. In this paper, a Maximum a Posteriori (MAP) estimation approach has been used to estimate the parameters of the untied triphone model set used in data-driven clust...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 174 3 شماره
صفحات -
تاریخ انتشار 2000