An energy minimization method for the correction of cupping artifacts in cone‐beam CT

نویسندگان

  • Shipeng Xie
  • Wenqin Zhuang
  • Haibo Li
چکیده

The purpose of this study was to reduce cupping artifacts and improve quantitative accuracy of the images in cone-beam CT (CBCT). An energy minimization method (EMM) is proposed to reduce cupping artifacts in reconstructed image of the CBCT. The cupping artifacts are iteratively optimized by using efficient matrix computations, which are verified to be numerically stable by matrix analysis. Moreover, the energy in our formulation is convex in each of its variables, which brings the robustness of the proposed energy minimization algorithm. The cupping artifacts are estimated as a result of minimizing this energy. The results indicate that proposed algorithm is effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. The proposed method focuses on the reconstructed image without requiring any additional physical equipment; it is easily implemented and provides cupping correction using a single scan acquisition. The experimental results demonstrate that this method can successfully reduce the magnitude of cupping artifacts. The correction algorithm reported here may improve the uniformity of the reconstructed images, thus assisting the development of perfect volume visualization and threshold-based visualization techniques for reconstructed images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Empirical cupping correction: a first-order raw data precorrection for cone-beam computed tomography.

We propose an empirical cupping correction (ECC) algorithm to correct for CT cupping artifacts that are induced by nonlinearities in the projection data. The method is raw data based, empirical, and requires neither knowledge of the x-ray spectrum nor of the attenuation coefficients. It aims at linearizing the attenuation data using a precorrection function of polynomial form. The coefficients ...

متن کامل

X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT.

Soft tissue images from portable cone beam computed tomography (CBCT) scanners can be used for diagnosis and detection of tumor, cancer, intracerebral hemorrhage, and so forth. Due to large field of view, X-ray scattering which is the main cause of artifacts degrades image quality, such as cupping artifacts, CT number inaccuracy, and low contrast, especially on soft tissue images. In this work,...

متن کامل

Analysis of Dose Calculation Accuracy in Cone Beam Computed Tomography with Various Amount of Scattered Photon Contamination

Cone-beam computed tomography (CBCT) images have inaccurate CT numbers because of scattered photons. Thus, quantitative analysis of scattered photons that affect an electron density (ED) curve and calculated doses may be effective information to achieve CBCT-based radiation treatment planning. We quantitatively evaluated the effect of scattered photons on the accuracy of dose calculations from ...

متن کامل

Beam Attenuation Grid–Based Scatter Correction Algorithm for Cone Beam Volume CT

In the flat panel detector-based cone beam CT system, the scatter photons which reach the flat panel detector increase the detected signal, produce the image cupping artifact and reduce the image contrast. To conquer the X-Ray scatter problem, this study proposes the beam attenuation grid -based scatter correction algorithm that needs to add a beam attenuation grid (BAG) between the X-Ray sourc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016