Baseline of Current Practise at ABB APR
نویسندگان
چکیده
A study to establish the current practise of the verification and validation process at ABB Automation Product AB (ABB APR) has been performed. The study is performed in cooperation between the Department of Communication Systems and ABB Automation Product AB (ABB APR). It is concluded that several basic process element are at place at ABB APR. The process used is basically a waterfall model. The process, called the Gate model, is largely followed. However, the process lack details and quality. The phases are defined, but the activities in each phase are ill-defined, both including purpose and content .This leads to a poor internal delivery quality, leaving too many defects in the product when entering the latter phases of testing and development. Also, the data collection procedures lack in granularity. Mainly the time collection procedures lack details. Finally, the overall training in verification and validation techniques is very low amongst the developers and testers.
منابع مشابه
Transcranial direct current stimulation facilitates motor learning post-stroke: a systematic review and meta-analysis.
Transcranial direct current stimulation (tDCS) is an attractive protocol for stroke motor recovery. The current systematic review and meta-analysis investigated the effects of tDCS on motor learning post-stroke. Specifically, we determined long-term learning effects by examining motor improvements from baseline to at least 5 days after tDCS intervention and motor practise. 17 studies reported l...
متن کاملClinical disease activity and acute phase reactant levels are discordant among patients with active rheumatoid arthritis: acute phase reactant levels contribute separately to predicting outcome at one year
INTRODUCTION Clinical trials of new treatments for rheumatoid arthritis (RA) typically require subjects to have an elevated acute phase reactant (APR), in addition to tender and swollen joints. However, despite the elevation of individual components of the Clinical Disease Activity Index (CDAI) (tender and swollen joint counts and patient and physician global assessment), some patients with act...
متن کاملEvaluating CM: Problem Management
CM: Problem Management is a detailed problem management process model to be utilised within corrective maintenance. It has been developed at ABB and evaluated for its industrial relevance within 17 non-ABB organisations. In this paper, we present the evaluation results of CM: Problem Management. Our primary goal is to confirm its industrial relevance. Our secondary goal is to establish current ...
متن کاملSoftware Process Improvement at Abb - Common Issues and Lessons Learnt
The growing importance of software for products as well as processes has been recognised in several ABB companies. As a result they started initiatives to improve their software development. Unlike other improvement programmes in industry, ABB‘s software process improvement initiatives are not part of company-wide, globally controlled programme. They rather evolved locally in different ABB comp...
متن کاملCurrent voltage measurements of electrolyte filled microelectrodes with ohmig and rectifying properties.
In Übereinstimmung mit der vorangegangenen, theoretischen Ableitung hängen der Widerstand (R0) und die Stromspannungs [i-E) -Kurven von Mikropipetten, die als Elektroden in der Elektrophysiologie verwendet werden, vom Radius r0[cm] und der Konzentration c[Äq./cm 3] des Elektro lyten ab. Große Werte von r0 c [Äq./cm2] entsprechen Volumenleitung in der Öffnung. /?0vol ^ 1/ r0 c Abb. 3; die i-£-K...
متن کامل