Mechanical properties of orthodontic wires derived by instrumented indentation testing (IIT) according to ISO 14577

نویسندگان

  • Spiros Zinelis
  • Youssef S Al Jabbari
  • Marianna Gaintantzopoulou
  • George Eliades
  • Theodore Eliades
چکیده

BACKGROUND The aim of this study was the characterization of mechanical properties of representative types of orthodontic wires employing instrumented indentation testing (IIT) according to ISO 14577. METHODS Segments were cut from ten wires. The first six are made of stainless steel (SS), two are made of Ni-Ti, and the last two are made of titanium molybdenum alloys (TMA). Then, the Martens hardness (HM), the Vickers hardness (HVIT) based on indentation hardness (H IT), the indentation modulus (E IT), the ratio of elastic to total work (η IT), and the traditional Vickers hardness (HV1) were measured by IIT. The results were statistically analyzed by one-way ANOVA followed by Student-Newman-Keuls (SNK) test at a = 0.05. The HVIT and HV1 data were analyzed by paired t test (a = 0.05). RESULTS SS wires showed the highest hardness followed by TMA and Ni-Ti alloys. However, all wires showed significantly lower HVIT compared to corresponding HV1, a finding probably appended to elastic recovery around the indentation. E IT for all wires tested was determined much lower than the nominal values of the corresponding alloys due to the implication of residual stress field at the slope of unloading curve. Elastic to total work ratio was ranged from 45.8 to 64.4 % which is higher than that expected for ductile alloys (<30 %). CONCLUSIONS The products tested illustrated significant differences in their mechanical properties. Although IIT provides reliable data for hardness and elastic index of materials tested, the intense residual stress field developed during the manufacturing process significantly affects the determination of modulus of elasticity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Instrumented Indentation Testing

INSTRUMENTED INDENTATION TESTING (IIT), also known as depth-sensing indentation, continuous-recording indentation, ultra-low-load indentation, and nanoindentation, is a relatively new form of mechanical testing that significantly expands on the capabilities of traditional hardness testing. Developed largely over the past two decades, IIT employs high-resolution instrumentation to continuously c...

متن کامل

Conventional Vickers and true instrumented indentation hardness determined by instrumented indentation tests

We evaluate Vickers hardness and true instrumented indentation test (IIT) hardness of 24 metals over a wide range of mechanical properties using just IIT parameters by taking into account the real contact morphology beneath the Vickers indenter. Correlating the conventional Vickers hardness, indentation contact morphology, and IIT parameters for the 24 metals reveals relationships between conta...

متن کامل

Do the mechanical and chemical properties of InvisalignTM appliances change after use? A retrieval analysis.

AIM To investigate the mechanical and chemical alterations of Invisalign appliances after intraoral aging. MATERIALS AND METHODS Samples of Invisalign appliances (Align Technology, San Jose, California, USA) were collected following routine treatment for a mean period of 44±15 days (group INV), whereas unused aligners of the same brand were used as reference (group REF). A small sample from t...

متن کامل

FEATURE Nanomechanical Characterization of Materials by Nanoindentation Series

I nstrumented indentation testing (IIT) is a technique for measuring the mechanical properties of materials. It is a development of traditional hardness tests such as Brinell, Rockwell, Vickers, and Knoop. IIT is similar to traditional hardness testing in that a hard indenter, usually diamond, is pressed into contact with the test material. However, traditional hardness testing yields only one ...

متن کامل

Microstructural and mechanical characterization of contemporary lingual orthodontic brackets.

OBJECTIVES To investigate the composition and the microstructural and mechanical characterization of three different types of lingual brackets. MATERIALS AND METHODS Incognito™ (3M Unitek), In-Ovation L (DENTSPLY GAC) and STb™ (Light Lingual System, ORMCO) lingual brackets were studied under the scanning electron microscope employing backscattered electron imaging and their elemental composit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015