Application of Far Cortical Locking Technology in Periprosthetic Femoral Fracture Fixation: A Biomechanical Study.

نویسندگان

  • Mehran Moazen
  • Andreas Leonidou
  • Joseph Pagkalos
  • Arsalan Marghoub
  • Michael J Fagan
  • Eleftherios Tsiridis
چکیده

BACKGROUND Lack of fracture movement could be a potential cause of periprosthetic femoral fracture (PFF) fixation failures. This study aimed to test whether the use of distal far cortical locking screws reduces the overall stiffness of PFF fixations and allows an increase in fracture movement compared to standard locking screws while retaining the overall strength of the PFF fixations. METHODS Twelve laboratory models of Vancouver type B1 PFFs were developed. In all specimens, the proximal screw fixations were similar, whereas in 6 specimens, distal locking screws were used, and in the other six specimens, far cortical locking screws. The overall stiffness, fracture movement, and pattern of strain distribution on the plate were measured in stable and unstable fractures under anatomic 1-legged stance. Specimens with unstable fracture were loaded to failure. RESULTS No statistical difference was found between the stiffness and fracture movement of the two groups in stable fractures. In the unstable fractures, the overall stiffness and fracture movement of the locking group was significantly higher and lower than the far cortical group, respectively. Maximum principal strain on the plate was consistently lower in the far cortical group, and there was no significant difference between the failure loads of the 2 groups. CONCLUSION The results indicate that far cortical locking screws can reduce the overall effective stiffness of the locking plates and increase the fracture movement while maintaining the overall strength of the PFF fixation construct. However, in unstable fractures, alternative fixation methods, for example, long stem revision might be a better option.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Font: Times New Roman 10pt THE TITLE SHOULD BE IN ALL CAPITAL LETTERS AND AS CONCISE AS POSSIBLE

RATIONALE: The purpose of the current study is to establish the biomechanical rationale for the increased risk of periprosthetic fracture associated with locking screw constructs over conventional screw constructs. This is important because the promise of locking plates to increase fixation in osteoporotic bone must be balanced with the potential complication of a periprosthetic fracture. An un...

متن کامل

Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis

BACKGROUND AND PURPOSE Historically, the treatment of periprosthetic femoral fractures (PFFs) has been associated with a high frequency of complications and reoperations. The preferred treatment is internal fixation, a revision of the femoral stem, or a combination of both. An improved understanding of plate use during internal fixation, and the introduction of locking-plate osteosynthesis may ...

متن کامل

Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty.

PURPOSE Periprosthetic distal femur fracture after total knee arthroplasty due to the stress-shielding phenomenon is a challenging problem. Retrograde intramedullary nail (RIMN) or locking plate (LP) fixation with/without a strut allograft has been clinically used via less invasive stabilization surgery (LISS) for the treatment of these periprosthetic fractures. However, their biomechanical dif...

متن کامل

Mechanism for Rotational Stability in Cemented Implants

+Wilson, L J; Richards, C; Crawford, R +Queensland University of Technology [email protected] Introduction The removal of well-fixed cement is a difficult and time consuming aspect of femoral component revision. Various surgical techniques and instruments have been developed to facilitate cement removal: extended trochanteric osteotomy, cortical windows[1], cement removal osteotomes/gauges/r...

متن کامل

Internal fixation of a traumatic fracture around a hip resurfacing arthroplasty using the proximal femoral locking compression plate.

We report on a 40-year-old man who sustained a traumatic extracapsular fracture of the proximal femur with a Birmingham Hip Resurfacing in situ. It was decided to retain the resurfacing implant and a proximal femoral periarticular locking compression plate (Synthes) was used to stabilise the fracture. The patient regained full range of pain-free movement, and was bearing his full weight on the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 31 8  شماره 

صفحات  -

تاریخ انتشار 2016