Vibrating membrane devices deliver aerosols more efficient than standard devices: a study in a neonatal upper airway model.

نویسندگان

  • Sybrich Tiemersma
  • Stefan Minocchieri
  • Richard A van Lingen
  • Mathias Nelle
  • Sunalene G Devadason
چکیده

BACKGROUND Aerosol therapy in preterm infants is challenging, as a very small proportion of the drug deposits in the lungs. AIM Our aim was to compare efficiency of standard devices with newer, more efficient aerosol delivery devices. METHODS Using salbutamol as a drug marker, we studied two prototypes of the investigational eFlow(®) nebulizer for babies (PARI Pharma GmbH), a jet nebulizer (Intersurgical(®) Cirrus(®)), and a pressurized metered dose inhaler (pMDI; GSK) with a detergent-coated holding chamber (AeroChamber(®) MV) in the premature infant nose throat-model (PrINT-model) of a 32-week preterm infant (1,750 g). A filter or an impactor was placed below the infant model's "trachea" to capture the drug dose or particle size, respectively, that would have been deposited in the lung. RESULTS Lung dose (percentage of nominal dose) was 1.5%, 6.8%, and 18.0-20.6% for the jet nebulizer, pMDI-holding chamber, and investigational eFlow nebulizers, respectively (p<0.001). Jet nebulizer residue was 69.4% and 10.7-13.9% for the investigational eFlow nebulizers (p<0.001). Adding an elbow extension between the eFlow and the model significantly lowered lung dose (p<0.001). A breathing pattern with lower tidal volume decreased deposition in the PrINT-model and device residue (p<0.05), but did not decrease lung dose. CONCLUSIONS In a model for infant aerosol inhalation, we confirmed low lung dose using jet nebulizers and pMDI-holding chambers, whereas newer, more specialized vibrating membrane devices, designed specifically for use in preterm infants, deliver up to 20 times more drug to the infant's lung.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Why Should We Have a Periodic Safety and Performance Program for Medical Devices

Nowadays, more than 10,000 different types of medical devices can be found in hospitals.These devices used in medical centers and hospitals for monitoring and treatment of patients require periodic safety and performance checking in order to have confidence in their functioning and operation. Physicians need better accurate medical measurements in order to better diagnose diseases, monitor pati...

متن کامل

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

In Vitro Evaluation of Aerosols Delivered via the Nasal Route.

BACKGROUND Infants and young children are obligate nose breathers; therefore, a transnasal route seems the logical delivery method of inhaled aerosols. The efficiency of aerosol delivery depends on several factors, such as interface, type of nebulizer, and patient age and breathing pattern. We hypothesized that the use of a vibrating mesh nebulizer, a tight-fitting face mask, and a head model a...

متن کامل

Determination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward

Background: In Neonatal intensive care units (NICU) different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the inte...

متن کامل

In Vitro Surfactant and Perfluorocarbon Aerosol Deposition in a Neonatal Physical Model of the Upper Conducting Airways

OBJECTIVE Aerosol delivery holds potential to release surfactant or perfluorocarbon (PFC) to the lungs of neonates with respiratory distress syndrome with minimal airway manipulation. Nevertheless, lung deposition in neonates tends to be very low due to extremely low lung volumes, narrow airways and high respiratory rates. In the present study, the feasibility of enhancing lung deposition by in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of aerosol medicine and pulmonary drug delivery

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2013