Robust measures of three-dimensional vascular tortuosity based on the minimum curvature of approximating polynomial spline fits to the vessel mid-line.

نویسندگان

  • Michael J Johnson
  • Geoff Dougherty
چکیده

The clinical recognition of abnormal vascular tortuosity is important in the diagnosis of many diseases. This paper presents a novel approach to the quantification of vascular tortuosity, using robust metrics based on unit speed parameterizations of three-dimensional (3D) curvature. The use of approximating polynomial spline-fitting obviates the need for arbitrary filtering of mid-line data which is necessary with other tortuosity indices. The metrics were tested using both two-dimensional and three-dimensional synthesized images that mimicked clinically significant pathologies: two of the three metrics were scale invariant, additive, and produced tortuosity values tailored to be independent of the resolution of the imaging system. Our methodology is designed to explicitly handle the challenge of noisy data, and is largely tolerant of the inaccuracies in the mid-line extraction. While all the proposed metrics are sensitive to gently curved vessels, the rms curvature of the smoothest path was more effective in recognizing abnormalities involving high-frequency coiling such as occurs in malignant tumors. We have also indicated how values from two projection images, such as acquired in biplane angiography, can be combined to give an accurate approximation of the 3D value of this metric. Our proposed methodology is well-suited to automated detection and measurement, which are a prerequisite for clinical implementation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical validation of three-dimensional tortuosity metrics based on the minimum curvature of approximating polynomial splines.

The clinical recognition of abnormal vascular tortuosity is important in the diagnosis of many diseases. Metrics based on three-dimensional (3D) curvature, using approximating polynomial spline-fitting to "data balls" centered along the mid-line of the vessel, minimize digitization errors and give tortuosity values largely independent of the resolution of the imaging system. We applied two of t...

متن کامل

NUMERICAL SOLUTION OF ONE-DIMENSIONAL HEAT AND WAVE EQUATION BY NON-POLYNOMIAL QUINTIC SPLINE

This paper present a novel numerical algorithm for the linear one-dimensional heat and wave equation. In this method, a nite dierenceapproach had been used to discrete the time derivative while cubic spline isapplied as an interpolation function in the space dimension. We discuss theaccuracy of the method by expanding the equation based on Taylor series andminimize the error. The proposed metho...

متن کامل

Curvature Based Biomarkers for Diabetic Retinopathy via Exponential Curve Fits in SE(2)

We propose a robust and fully automatic method for the analysis of vessel tortuosity. Our method does not rely on pre-segmentation of vessels, but instead acts directly on retinal image data. The method is based on theory of best-fit exponential curves in the roto-translation group SE(2). We lift 2D images to 3D functions called orientation scores by including an orientation dimension in the do...

متن کامل

Computational simulations of nanoparticle transport in a three-dimensional capillary network

Objective(s): Multifunctional nanomedicine is the new generation of medicine, which is remarkably promising and associated with the minimum toxicity of targeted therapy. Distribution and transport of nanoparticles (NPs) in the blood flow are essential to the evaluation of delivery efficacy. Materials and Methods: In the present study, we initially designed a phantom based on Murray’s mini...

متن کامل

Investigation of pore-scale random porous media using lattice boltzmann method

The permeability and tortuosity of pore-scale two and three-dimensional random porous media were calculated using the Lattice Boltzmann method (LBM). Effects of geometrical parameters of medium on permeability and tortuosity were investigated as well. Two major models of random porous media were reconstructed by computerized tomography method: Randomly distributed rectangular obstacles in a uni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 2007