[Anophthalmic cavity and implant extrusion].
نویسندگان
چکیده
PURPOSE To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion. METHODS A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere extrusion at the "Faculdade de Medicina de Botucatu-UNESP". RESULTS Extrusion was observed in enucleated and eviscerated cavities. The majority of the patients had the eye removed because of phthisis bulbi or trauma and the extrusion happened 1 or 2 years after the surgery. Extrusion was preceded by conjunctival dehiscence and exposure of the sphere and occurred with all used implants. CONCLUSION Complications after orbital implant placement are a possibility. Dehiscence and sphere extrusion may happen and another surgery would be necessary. The patient and the ophthalmologist have to be prepared for this.
منابع مشابه
Use of Proplast II as a subperiosteal implant for the correction of anophthalmic enophthalmos.
BACKGROUND A variety of autogenous and alloplastic materials have been used as subperiosteal implants to correct anophthalmic enophthalmos. Proplast II is a synthetic porous composite of Teflon polymer and alumina. Proplast II offers a number of advantages over other commonly used alloplastic materials such as silicone and polymethyl methacrylate. It is light, porous, resilient, malleable, and ...
متن کاملAutogenous dermis-fat orbital impant for anophthalmic socket.
To our knowledge, there is no report of dermis-fat graft (DFG) implant for orbital reconstruction from Oman. We hereby presented a case report of a 10-year-old boy with a blind and painful left eye secondary to penetrating eye injury presented with implant extrusion following evisceration with a polymethyl methacrylate implant. The evisceration procedure was converted to enucleation and a DFG o...
متن کاملIndications and results in anophthalmic socket reconstruction using dermis-fat graft
OBJECTIVES To present the indications for a dermis-fat graft in anophthalmic socket reconstruction and evaluate the results of this procedure. DESIGN Retrospective review, interventional case series. METHODS In our study, there were 41 patients who received either primary or secondary dermis-fat graft between August 1, 2007 and July 31, 2012 at Songklanagarind Hospital. RESULTS The type o...
متن کاملComplications in motility PEG placement for hydroxyapatite orbital implant in anophthalmic socket.
PURPOSE In a retrospective study, we evaluated the complications in using the motility peg system (nonsleeved and sleeved) for hydroxyapatite orbital implants in an anophthalmic socket. METHODS Drilling for motility peg placement was performed in 265 patients with hydroxyapatite implantation: nonsleeved peg system (n = 191), sleeved peg system (n = 74). A statistical analysis was performed us...
متن کاملOrbital growth after unilateral enucleation in infancy without an orbital implant.
PURPOSE To measure the volume of the anophthalmic orbit in adults who had undergone enucleation during infancy and to determine its growth. METHODS The orbital volume in 5 adults who had undergone unilateral enucleation during infancy without an orbital implant was measured on x-ray computed tomography images. Comparisons were made between the anophthalmic and normal sides. In addition, we ev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 70 5 شماره
صفحات -
تاریخ انتشار 2007