Applanation and Schiotz tonometer standardizations for the owl monkey eye with a new technique for measuring episcleral venous pressure.
نویسندگان
چکیده
A Schi0tz Pi calibration by open manometer was performed on 18 owl monkey eyes cannulated in situ. Pi values for the owl monkey corresponded closely to those of the 1955 Friedenwald nomogram. The average ocular rigidity measured in 16 additional eyes with the use of clinical techniques was 0.0173 (± 0.0015). A manometric calibration for a 4 mm. diameter applanation face was done similarly on 21 eyes. The following standardization formula ivas generated: Pressure in mm. Hg = 0.641 (tonometric scale reading) + 2.56 mm. Hg. An attempt ivas made to compare the two tonometric pressure standardizations. In 16 intact eyes, Schi0tz PO pressures, corrected for ocular rigidity, averaged 0.77 ± 0.47 mm. Hg higher than corresponding applanation pressures. An improved method for measuring episcleral venous pressure, xoith the use of a new synthetic polyurethane pressure chamber membrane, is also reported.
منابع مشابه
Applanation and Schi0tz tonometer standardizations for the owl monkey eye with a new technique for measuring episcleral venous pressure
A Schi0tz Pi calibration by open manometer was performed on 18 owl monkey eyes cannulated in situ. Pi values for the owl monkey corresponded closely to those of the 1955 Friedenwald nomogram. The average ocular rigidity measured in 16 additional eyes with the use of clinical techniques was 0.0173 (± 0.0015). A manometric calibration for a 4 mm. diameter applanation face was done similarly on 21...
متن کاملComparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
PURPOSE Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonom...
متن کاملSchiötz tonometers. An assessment of their usefulness.
THERE is no doubt that applanation tonometry gives more accurate information about the level of intra-ocular pressure than does indentation tonometry. This increased accuracy is due to the fact that applanation readings approach very closely to the levels of pressure in the undisturbed eye (Po), owing to the small volume of fluid displaced by the application of the tonometer (Goldmann, 1957). A...
متن کاملEPISCLERAL VENOUS PRESSURE IN TONOGRAPHY * t BY ARTHUR
DURING the 11 years in which the clinical measurement of facility of outflow by means of tonography has been practised, various workers have sought to elucidate and correct the sources of error inherent in this method. One of the assumptions originally made concerning tonography was that the episcleral venous pressure was not disturbed during the measurement. Friedenwald (Grant, 1951) and Becke...
متن کاملThe effect of miotics on the intraocular pressure of conscious owl monkeys.
The intraocular pressure of conscious, unsedated owl monkeys (Aotus trivirgatus) was measured with an applanation tonometer. Untreated eyes of the conscious animals were found to have higher values than those reported for owl monkeys anesthetized with pentobarbitone. Locally applied pilocarpine, carbachol, and oxotremorine gave concentration-related reduction in pressure, oxotremorine being the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology
دوره 10 3 شماره
صفحات -
تاریخ انتشار 1971