Combination of Heat Shock and Enhanced Thermal Regime to Control the Growth of a Persistent Legionella pneumophila Strain

نویسندگان

  • Emilie Bédard
  • Inès Boppe
  • Serge Kouamé
  • Philippe Martin
  • Linda Pinsonneault
  • Louis Valiquette
  • Jules Racine
  • Michèle Prévost
چکیده

Following nosocomial cases of Legionella pneumophila, the investigation of a hot water system revealed that 81.5% of sampled taps were positive for L. pneumophila, despite the presence of protective levels of copper in the water. A significant reduction of L. pneumophila counts was observed by culture after heat shock disinfection. The following corrective measures were implemented to control L. pneumophila: increasing the hot water temperature (55 to 60 °C), flushing taps weekly with hot water, removing excess lengths of piping and maintaining a water temperature of 55 °C throughout the system. A gradual reduction in L. pneumophila counts was observed using the culture method and qPCR in the 18 months after implementation of the corrective measures. However, low level contamination was retained in areas with hydraulic deficiencies, highlighting the importance of maintaining a good thermal regime at all points within the system to control the population of L. pneumophila.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of heat shock on hot water plumbing microbiota and Legionella pneumophila control

BACKGROUND Heat shock is a potential control strategy for Legionella pneumophila in hot water plumbing systems. However, it is not consistently effective, with little understanding of its influence on the broader plumbing microbiome. Here, we employed a lab-scale recirculating hot water plumbing rig to compare the pre- and post-"heat shock" (i.e., 40 → 60 → 40 °C) microbiota at distal taps. In ...

متن کامل

Isolation of Legionella pneumophila from Tehran Hospital Water Samples

Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...

متن کامل

An Investigation of the Legionella Pneumophila Infection in Pneumonic Patients in Three Different Infections Hospital Wards in Tehran

Legionella pneumophila is one of the causative agent of pneumonia in human being. In recent years many reports has been come from different parts of world regarding infectivity of this organism. This disease occurs almost because of contamination of air conditioning systems. For the purpose of assessment of the legionella pneumophila in pneumonic patients, 200 specimen from sputum and tracheo-b...

متن کامل

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

Isolation and identification of Legionella spp. from different aquatic sources in south-west of Iran by molecular &culture methods

Legionella pneumophila, the causative agent of Legionnaires’ diseases (LD) is usually transmitted to humans via inhalation of aerosols from contaminated natural and manmade water sources. These organisms may become fatal especially in immunocompromised patients and LD is the one of the important disease from a public health perspective. This survey investigated the frequency of Legionella spp. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016