When we research the suppression problem of subsynchronous oscillation based on time domain simulation method, we find the appropriate parameters for phase compensation and amplitude gaining links are important to the damping effect of the additional damping controllers, supplementary excitation damping controller(SEDC) and subsynchronous supplementary damping controller(SSDC). Some scholars attempt to optimize parameters by various optimization algorithms. But when they are applied in the complex system, there might have some practical problems. A novel method--simulation test method, which is simple but practical, is introduced in this paper. We can effectively identify the compensation phase and gain coefficient by this way, combined with test signal method. The specific design of SEDC and SSDC is realized in this paper. With these parameters obtained, SEDC and SSDC have a good inhibitory effectiveness. So the feasibility of this new method is validated. It is of great significance for engineering research. Keyword subsynchronous oscillation(SSO);supplementary excitation damping controller(SEDC); subsynchronous supplementary damping controller (SSDC); time domain simulation method
منابع مشابه
Robust Coordinated Design of UPFC Damping Controller and PSS Using Chaotic Optimization Algorithm
A Chaotic Optimization Algorithm (COA) based approach for the robust coordinated design of the UPFC power oscillation damping controller and the conventional power system stabilizer has been investigated in this paper. Chaotic Optimization Algorithms, which have the features of easy implementation, short execution time and robust mechanisms of escaping from local optimum, is a promising tool fo...
متن کاملMitigation of SSR Oscillations in Series Compensated Line using LCAP Subsynchronous Damping Controller
Subsynchronous Resonance (SSR) is a growing problem in power systems having series compensated transmission lines. Subsynchronous resonance with low frequency that surpasses aggregate fatigue threshold of the generator shaft frequently could significantly reduce the shaft service life, which is a new problem that emerges in recent years. Flexible AC transmission systems (FACTS) controllers are ...
متن کاملResearch on Shaft Subsynchronous Oscillation Characteristics of Parallel Generators and SSDC Application in Mitigating SSO of Multi-Generators
Subsynchronous oscillation (SSO) of generators caused by high voltage direct current (HVDC) systems can be solved by applying supplemental subsynchronous damping controller (SSDC). SSDC application in mitigating SSO of single-generator systems has been studied intensively. This paper focuses on SSDC application in mitigating SSO of multi-generator systems. The phase relationship of the speed si...
متن کاملAn Optimal Reactive Power Control Strategy for a DFIG-Based Wind Farm to Damp the Sub-Synchronous Oscillation of a Power System
This study presents the auxiliary damping control with the reactive power loop on the rotor-side converter of doubly-fed induction generator (DFIG)-based wind farms to depress the sub-synchronous resonance oscillations in nearby turbogenerators. These generators are connected to a series capacitive compensation transmission system. First, the damping effect of the reactive power control of the ...
متن کاملAn active power control strategy for a DFIG-based wind farm to depress the subsynchronous resonance of a power system
This study presents a novel auxiliary damping control strategy to depress subsynchronous resonance (SSR) oscillations in nearby turbine generators. In the proposed control strategy, SSR damping is achieved by adding turbine generator speed as a supplementary signal at the active power loop of the rotor-side converter (RSC) of doubly-fed induction generator (DFIG)-based wind farms. To design the...