Film bulk acoustic resonators (FBARs) have been evaluated for use as biosensors because of their high sensitivity and small size. This study fabricated a novel human IgE biosensor using shear-mode FBAR devices with c-axis 23°-tilted AlN thin films. Off-axis radio frequency (RF) magnetron sputtering method was used for deposition of c-axis 23°-tilted AlN thin films. The deposition parameters were adopted as working pressure of 5 mTorr, substrate temperature of 300°C, sputtering power of 250 W, and 50 mm distance between off-axis and on-axis. The characteristics of the AlN thin films were investigated by X-ray diffraction and scanning electron microscopy. The frequency response was measured with an HP8720 network analyzer with a CASCADE probe station. The X-ray diffraction revealed (002) preferred wurtzite structure, and the cross-sectional image showed columnar structure with 23°-tilted AlN thin films. In the biosensor, an Au/Cr layer in the FBAR backside cavity was used as the detection layer and the Au surface was modified using self-assembly monolayers (SAMs) method. Then, the antigen and antibody were coated on biosensor through their high specificity property. Finally, the shear-mode FBAR device with k t (2) of 3.18% was obtained, and the average sensitivity for human IgE detection of about 1.425 × 10(5) cm(2)/g was achieved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A FEASIBILITY STUDY OF ZnO - BASED FBAR DEVICES FOR AN ULTRA - MASS - SENSITIVE SENSOR APPLICATION

We present a feasibility study of ZnO-based FBAR devices and their fabrications for the ultra-mass-sensitive sensor application. In this work, a considerable shift in the resonance frequency is observed due to the mass-loading effect by a mixture of ink and volatile methanol. A high sensitivity of 0.05 10 Hz cm/ng is obtained in the FBAR-based device, which is 5 orders of magnitude higher than ...

متن کامل

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

TWO-STAGE METHOD FOR DAMAGE LOCALIZATION AND QUANTIFICATION IN HIGH-RISE SHEAR FRAMES BASED ON THE FIRST MODE SHAPE SLOPE

In this paper, a two-stage method for damage detection and estimation in tall shear frames is presented. This method is based on the first mode shape of a shear frame. We demonstrate that the first mode shape slope is very sensitive to the story stiffness. Thus, at the first stage, by using the grey system theory on the first mode shape slope, damage locations are identified in shear frames. Da...

متن کامل

Improved Resonance Characteristics by Thermal Annealing of W/SiO2 Multi-Layers in Film Bulk Acoustic Wave Resonator Devices

In this paper, we, for the first time, present the effects of the thermal annealing of the W/SiO 2 multi-layer Bragg reflectors on the resonance characteristics of the ZnO-based film bulk acoustic wave resonator (FBAR) devices. In order to improve the resonance characteristics of the FBAR devices, we employed a thermal annealing process after the Bragg reflectors were formed on a silicon substr...

متن کامل

Development of a Quartz Crystal Microbalance Biosensor with Aptamers as Bio-recognition Element

The ultimate goal in any biosensor development project is its use for actual sample detection. Recently, there has been an interest in biosensors with aptamers as bio-recognition elements, but reported examples all deal with standards, not human serum. In order to verify the differences of aptamer-based biosensor and antibody-based biosensor in clinical detection, a comparison of the performanc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015