An anthropomorphic polyvinyl alcohol brain phantom based on Colin27 for use in multimodal imaging.

نویسندگان

  • Sean Jy-Shyang Chen
  • Pierre Hellier
  • Maud Marchal
  • Jean-Yves Gauvrit
  • Romain Carpentier
  • Xavier Morandi
  • D Louis Collins
چکیده

PURPOSE In this paper, the method for the creation of an anatomically and mechanically realistic brain phantom from polyvinyl alcohol cryogel (PVA-C) is proposed for validation of image processing methods such as segmentation, reconstruction, registration, and denoising. PVA-C is material widely used in medical imaging phantoms because of its mechanical similarities to soft tissues. METHODS The phantom was cast in a mold designed using the left hemisphere of the Colin27 brain dataset [C. Holmes et al., "Enhancement of MR images using registration for signal averaging," J. Comput. Assist. Tomogr. 22(2), 324 (1998)]. Marker spheres and inflatable catheters were also implanted to enable good registration comparisons and to simulate tissue deformation, respectively. RESULTS The phantom contained deep sulci, a complete insular region, and an anatomically accurate left ventricle. It was found to provide good contrast in triple modality imaging, consisting of computed tomography, ultrasound, and magnetic resonance imaging. Multiple sets of multimodal data were acquired from this phantom. CONCLUSIONS The methods for building the anatomically accurate, multimodality phantom were described in this work. All multimodal data are made available freely to the image processing community (http://pvabrain.inria.fr). We believe the phantom images could allow for the validation and further aid in the development of novel medical image processing techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Anthropomorphic Polyvinyl Alcohol Triple-Modality Brain Phantom Based on Colin27

We propose a method for the creation of an anatomically and mechanically realistic brain phantom from polyvinyl alcohol cryogel (PVA-C) for validation of image processing methods for segmentation, reconstruction, registration, and denoising. PVA-C is material widely used in medical imaging phantoms for its mechanical similarities to soft tissues. The phantom was cast in a mold designed using th...

متن کامل

A Short Study Report For Phantom Investigation

1. Polyvinyl Alcohol Phantoms (Polyvinyl alcohol gels) Polyvinyl alcohol cryogel (PVA-C) is a typical tissue-mimicking material for ultrasound imaging. It is formed from PVA solution undergoing some freezethaw (F/T) cycles. As the optical and mechanical properties change with the number of F/T cycle, certain requirements, like the scattering coefficient and absorption coefficient, for the phant...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

یک فانتوم سر ریاضیاتی برای بررسی‌های دوزیمتری به روش مونت‌کارلو

Introduction: In diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. Monte Carlo methods are used due to the high complexity and cost of patient-specific phantom construction. The high complexity of the digitized phantoms greatly increases the time and computational task of the Monte Carlo calculati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 1  شماره 

صفحات  -

تاریخ انتشار 2012