Design and evaluation of a prosthesis control system based on the concept of extended physiological proprioception.
نویسندگان
چکیده
This paper describes the design and evaluation of an experimental prosthesis-control system based on the concept of extended physiological proprioception (EPP). It was originally hypothesized that EPP control effected by residual shoulder motion could be effectively applied in multifunctional prostheses for shoulder disarticulation amputees. The experimental system developed for this study utilized a force-driven control scheme and a shoulder motion transduction system in which direct cable linkages to the prosthesis components were used to implement EPP position-servo relationships between shoulder elevation-depression and prosthesis elbow flexion, and between shoulder protraction-retraction and prosthesis wrist rotation. The results of experiments performed with this prosthesis (and with an experimental velocity-controlled prosthesis implemented for comparison purposes) clearly demonstrated the superior performance provided by EPP control of prosthesis function.
منابع مشابه
The effects of static friction and backlash on extended physiological proprioception control of a powered prosthesis.
In general, externally powered prostheses do not provide proprioceptive feedback and thus require the user to rely on cognitively expensive visual feedback to effectively control the prosthesis. Applying the concept of extended physiological proprioception (EPP) to externally powered prostheses provides direct feedback to the user's proprioceptive system regarding the position, velocity, and fo...
متن کاملAn analysis of extended physiological proprioception as a prosthesis-control technique.
This research was devoted to an investigation of the practicality and potential effectiveness of applying the concept of extended physiological proprioception (EPP) to the control of upper-limb prostheses. The purpose of this study was to verify that EPP control, implemented by coupling prosthesis function to residual shoulder motion in a position-servo relationship, could be effectively applie...
متن کاملProsthetic Control: a Case for Extended Physiological Proprioception
To achieve subconscious prosthetic control the patient feedback present must be employed as completely as possible. This implies the use of control methods based upon the principles of extended physiological proprioception. The harnessing of body movements has the inherent ability to fully employ the principles of extended physiological proprioception. However, the present harnessing techniques...
متن کاملEvaluation of a Viscoelastic Ankle-Foot Prosthesis at Slow and Normal Walking Speeds on an Able-Bodied Subject
Objectives: This paper describes further improvement and preliminarily evaluation of a novel viscoelastic ankle-foot prosthesis prototype. The objective was to control the ankle hysteresis at slow and normal walking speeds. Methods: Inspired by the ankle biomechanics, in which the hysteresis differs based on the gait speeds, a manually damping control mechanism imbedded in the prosthesis for...
متن کاملFormulation and Evaluation of Extended- Release Tablet of Zolpidem Tartrate by Wet Granulation Technique
The goal of this study was to design and evaluate extended - release system of the hypnotic agent, Zolpidemtartrate usefulness for the treatment of insomnia. The half-life of this drug is about 1.9 - 3 hours that indicatingit a candidate for the extended release formulation. Our investigation relates to development of extendeddrug delivery system based on Hydroxy propyl methyl cellulose (HPMCK4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 21 1 شماره
صفحات -
تاریخ انتشار 1984