A multicentric evaluation of IDMS-traceable creatinine enzymatic assays.
نویسندگان
چکیده
Chronic kidney disease definition is based on glomerular filtration rate (GFR) estimations which are derived from creatinine-based equations. The accuracy of GFR estimation is thus largely dependent of those of serum creatinine assays. International recommendations highlight the need for traceable creatinine assays. The French Society of Clinical Biochemistry conducted a study for measuring accuracy of creatinine enzymatic methods. This evaluation involved 25 clinical laboratories. Creatinine was measured in serum pools ranging from 35.9±0.9 μmol/L to 174.5±3.1 μmol/L (IDMS determination) using 12 creatinine enzymatic methods. For all creatinine values greater than 74.4±1.4 μmol/L, the bias and imprecision did not exceed 5% and 5.9%, respectively. For the lowest value (35.9±0.9 μmol/L), the bias ranged from -1.8 to 9.9% (with one exception). At this level, the imprecision ranged from 1.9 to 7.8%. The true performances of the assays (couples of bias and relative standard deviation), were evaluated using Monte-Carlo simulations. Most of the assays fall within the maximum Total Error of 12% at all concentrations. This study demonstrates substantial improvements in the calibration, traceability and precision of the enzymatic methods, reaching the NKDEP recommendations. Moreover, most of these assays allowed accurate creatinine measurements for creatinine levels lower than 40 μmol/L.
منابع مشابه
Paired measurement of urinary creatinine in neonates based on a Jaffe and an enzymatic IDMS-traceable assay
BACKGROUND Urinary creatinine can be quantified by Jaffe or enzymatic assays and is commonly used as denominator of urinary excretion of electrolytes or protein. Paired analysis in pediatric and adult samples documented inter-assay differences (up to 80%). We verified the interchangeability of two IDMS-traceable assays (Jaffe and enzymatic) for neonatal urine and report on neonatal urinary crea...
متن کاملApplicability of common reference intervals for serum creatinine concentrations to the Croatian population.
BACKGROUND In accordance with an ongoing activity for worldwide harmonization based on traceability in laboratory methods, the goal of this study was to validate the applicability of recommended "common" reference intervals for serum creatinine concentrations using a specific enzymatic method to the Croatian population. METHODS The reference group consisted of 240 healthy subjects (120 males ...
متن کاملExpressing the Modification of Diet in Renal Disease Study equation for estimating glomerular filtration rate with standardized serum creatinine values.
PURPOSE We sought to reexpress the 4-variable Modification of Diet in Renal Disease (MDRD) Study equation for estimation of glomerular filtration rate (GFR) using serum creatinine (S(cr)) standardized to reference methods. METHODS Serum specimens included creatinine reference materials prepared by the College of American Pathologists (CAP), traceable to primary reference material at the NIST,...
متن کاملInvestigating interferences of a whole-blood point-of-care creatinine analyzer: comparison to plasma enzymatic and definitive creatinine methods in an acute-care setting.
BACKGROUND Although measurement of whole-blood creatinine at the point of care offers rapid assessment of renal function, agreement of point-of-care (POC) results with central laboratory methods continues to be a concern. We assessed the influence of several potential interferents on POC whole-blood creatinine measurements. METHODS We compared POC creatinine (Nova StatSensor) measurements wit...
متن کاملThe practical implications of using standardized estimation equations in calculating the prevalence of chronic kidney disease.
BACKGROUND Kidney Disease Outcomes Quality Initiative (KDOQI) chronic kidney disease (CKD) guidelines have focused on the utility of using the modified four-variable MDRD equation (now traceable by isotope dilution mass spectrometry IDMS) in calculating estimated glomerular filtration rates (eGFRs). This study assesses the practical implications of eGFR correction equations on the range of crea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinica chimica acta; international journal of clinical chemistry
دوره 412 23-24 شماره
صفحات -
تاریخ انتشار 2011