GlideScope Videolaryngoscopy in the Simulated Difficult Airway: Bougie vs Standard Stylet
نویسندگان
چکیده
OBJECTIVE GlideScope(®) videolaryngoscopy (GVL) has been shown to improve visualization of the glottis compared to direct laryngoscopy (DL). However, due to the angle of approach to the glottis, intubation can still be challenging. We hypothesized that novice GVL users would be able to intubate faster and easier using an airway introducer (frequently known as a bougie) than with a standard intubating stylet. METHODS Intubations were performed on a human airway simulator with settings for easy and difficult airways. Participants were emergency medicine (EM) residents or faculty (n=21) who were novice GVL users. Participants were intubated a total of eight times (four GVL, four DL) using either a bougie or an intubating stylet. We recorded time to intubate (TTI) and difficulty rating using a visual analog scale (VAS) and non-parametric statistical methods for analysis. We reported medians with interquartile range (IQR). RESULTS The median TTI with difficult airway settings and the bougie-GVL was 76 seconds (IQR 50, 102) versus 64 seconds (IQR 50.5, 125), p=0.76 for the stylet-GVL combination. The median VAS difficulty score, on difficult airway settings, for the bougie-GVL was 5 cm (IQR 3.3, 8.0) versus 6.2 cm (IQR 5.0, 7.5) with the stylet-GVL, p=0.53. CONCLUSION Among novices using GVL for simulated difficult airway management, there was no benefit, in terms of speed or ease of intubation, by using the bougie over the standard stylet.
منابع مشابه
A mannequin study of intubation with the AP advance and GlideScope Ranger videolaryngoscopes and the Macintosh laryngoscope.
BACKGROUND The AP Advance (APA) is a videolaryngoscope with interchangeable blades: intubators can choose standard Macintosh blades or a difficult-airway blade with increased curvature and a channel to guide the tube to the larynx. The APA may therefore be comparably effective in both normal and difficult airways. We tested the hypotheses that intubation with the APA is no slower than Macintosh...
متن کاملKnotting in peripherally inserted central catheters: more possible mechanisms.
References 1 Cooper RM. Use of a new video laryngoscope (GlideScope®) in the management of a difficult airway. Can J Anesth 2003; 50: 611–3. 2 Doyle DJ, Zura A, Ramachandran M. Videolaryngoscopy in the management of the difficult airway (Letter). Can J Anesth 2004; 51: 95. 3 Cooper RM. Videolaryngoscopy in the management of the difficult airway (Letter, reply). Can J Anesth 2004; 51: 95–6. 4 Ra...
متن کاملA good laryngeal view does not guarantee perfectly successful tracheal intubation
tracheal intubation is the most common factor related to serious airway complications during anesthesia [1]. Difficult tracheal intubation is defined as insertion of the endo-tracheal tube using direct laryngoscopy that requires more than two attempts lasting more than 10 min each or that requires an alternative technique [2]. The difficult airway involves interactions among patient factors, th...
متن کاملDifficult Intubation in Pediatric Patient with a Large Lymphangioma at the Tongue Base
Lymphangioma is a congenital malformation of lymphatic system and often involves the oral cavity. When lymphangioma is located on the mouth floor and enlarges, it can compress the airway and make intubation difficult. The GlideScope(®) video laryngoscope is sometimes used in routine intubation, but is most commonly used in difficult or failed intubation. We report a pediatric patient with a dif...
متن کاملParamedic use of the endotracheal tube introducer in a difficult airway model.
OBJECTIVES To determine whether advanced life support (ALS)-level prehospital providers can be taught to effectively use the Flex-Guide (FG) Endotracheal Tube (ETT) introducer in a difficult airway model by comparing success of styleted ETT intubation with Flex-Guide-assisted intubation. METHODS Intermediate and advanced providers, who brought patients to a Level 1 emergency department, were ...
متن کامل