Geometric calibration of Colour and Stereo Surface Imaging System of ESA's Trace Gas Orbiter

نویسندگان

  • Stepan Tulyakov
  • Anton Ivanov
  • Nicolas Thomas
  • Victoria Roloff
  • Antoine Pommerol
  • Gabriele Cremonese
  • Thomas Weigel
  • François Fleuret
چکیده

There are many geometric calibration methods for “standard” cameras. These methods, however, cannot be used for the calibration of telescopes with large focal lengths and complex off-axis optics. Moreover, specialized calibration methods for the telescopes are scarce in literature. We describe the calibration method that we developed for the Colour and Stereo Surface Imaging System (CaSSIS) telescope, on board of the ExoMars Trace Gas Orbiter (TGO). Although our method is described in the context of CaSSIS, with camera-specific experiments, it is general and can be applied to other telescopes. We further encourage re-use of the proposed method by making our calibration code and data available on-line.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometric calibration of Colour and Stereo Surface Imaging System of ESAâ€TMs Trace Gas Orbiter

There are many geometric calibration methods for ‘‘standard” cameras. These methods, however, cannot be used for the calibration of telescopes with large focal lengths and complex off-axis optics. Moreover, specialized calibration methods for the telescopes are scarce in literature. We describe the calibration method that we developed for the Colour and Stereo Surface Imaging System (CaSSIS) te...

متن کامل

Topographic Mapping of Mars: from Hectometer to Micrometer Scales

We describe USGS topomapping of Mars at resolutions from 100 m to 30 μm with data from the latest spacecraft missions. Analysis of NASA 2001 Mars Odyssey Thermal Emission Imaging System (THEMIS) data combining daytime visible reflected, daytime IR emitted, and nighttime IR emitted images allows us to isolate the physical effects of topography, albedo, and thermal inertia. To a good approximatio...

متن کامل

A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology

  Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and pr...

متن کامل

LROC Stereo Observations

McEwen, and Mark Robinson. Carl Sagan Center at the SETI Institute, NASA Ames Research Center, MS 245-3, Moffett Field, CA, USA ([email protected]), United States Geological Survey, Ohio State University, The University of Arizona, and Arizona State University The Lunar Reconnaissance Orbiter Camera (LROC) [1, 2] will obtain two types of multiple overlapping coverage to enable derivation of...

متن کامل

A Self-Calibration Bundle Adjustment Method for Photogrammetric Processing of Chang $^{\prime}$E-2 Stereo Lunar Imagery

Chang′E-2 (CE-2) lunar orbiter is the second robotic orbiter in the Chinese Lunar Exploration Program. The chargecoupled-device (CCD) camera equipped on the CE-2 orbiter acquired stereo images with a resolution of less than 10 m and global coverage. High-precision topographic mapping with CE-2 CCD stereo imagery is of great importance for scientific research, as well as for the landing preparat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • CoRR

دوره abs/1707.00606  شماره 

صفحات  -

تاریخ انتشار 2017