Comparison of oxygen saturation by pulse oximetry and co-oximetry during exercise testing in patients with COPD.

نویسندگان

  • J P McGovern
  • S A Sasse
  • D W Stansbury
  • L A Causing
  • R W Light
چکیده

INTRODUCTION Measurement of oxygen saturation by pulse oximetry (SpO2) is frequently performed during exercise testing of patients with COPD to monitor for hypoxemia. The purpose of this study was to assess the accuracy and precision of pulse oximetry during exercise. We hypothesized that the SpO2 would more closely reflect oxygen saturation as measured by co-oximetry (SaO2) when it was corrected for carboxyhemoglobin (COHb). We also hypothesized that SpO2 would more closely reflect SaO2 when the pulse rate by oximeter was equivalent to the heart rate by ECG. Finally, we hypothesized that SpO2 would be a better measure of SaO2 at maximal workloads than at rest or submaximal workloads. METHODS Eight white men with severe COPD (mean +/- SD FEV1, 0.91 +/- 0.37) underwent progressive, symptom-limited exercise testing by cycle ergometry. SaO2 was measured from arterial blood at each workload using a co-oximeter. SpO2 and pulse rate were obtained by a pulse oximeter (Ohmeda 3700). Heart rate was continuously monitored by ECG. RESULTS Reliable oximetric values as determined by a dicrotic notch in each waveform and adequate signal intensity were obtained in all eight patients. SpO2 was a moderately accurate measure of SaO2 (bias, 1.7%; precision, 2.9). The bias actually increased (4.1%) when SpO2 was corrected for COHb. Accuracy of SpO2 was not improved when pulse rate by oximetry and heart rate by ECG were equivalent, nor was the accuracy improved at maximal workloads relative to submaximal workloads during the exercise test. CONCLUSION Oxygen saturation as measured by pulse oximetry (SpO2) in patients with COPD undergoing exercise testing is not sufficiently accurate to replace SaO2 as the gold standard for oxygen saturation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of invasive and noninvasive saturation monitoring in prescribing oxygen during exercise in COPD patients.

The aim of this study was to determine whether it is possible using ear-oximetry to prescribe the correct oxygen flow rates during exercise in chronic obstructive pulmonary disease (COPD) patients on long-term oxygen therapy (LTOT). Twenty COPD patients on LTOT, with exercise desaturation breathing oxygen at resting flow rates, performed a series of 6-min treadmill walking tests, with a progres...

متن کامل

Effects of Pentoxifylline on Oxygenation and Exercise Tolerance in Patients with Severe Chronic Obstructive Pulmonary Disease

Background: It was hypothesized that the use of Pentoxifylline would increase arterial O2 saturation and increase exercise tolerance in patients with Chronic Obstructive Pulmonary Disease (COPD). Methods: We tested this hypothesis in 23 patients with COPD and pulmonary hypertension. Patients were randomized to receive Pentoxifylline or placebo, each for a 12-week period, in a prospectiv...

متن کامل

Assessing need for long-term oxygen therapy: a comparison of conventional evaluation and measures of ambulatory oximetry monitoring.

BACKGROUND Appropriate identification of hypoxic patients with chronic obstructive pulmonary disease (COPD) is important because of the demonstrated survival benefit of long-term oxygen therapy (LTOT) and its associated cost. Resting oxygen saturation (measured via pulse oximetry [S(pO2)]) and lowest exercise S(pO2) (during a 6-min walk test) is the standard method of determining LTOT requireme...

متن کامل

Pulse Oximetry Overestimates Oxygen Saturation in COPD.

BACKGROUND Measurement of oxygen saturation with a handheld pulse oximeter is widely practiced as a surrogate to invasive arterial blood gas analysis. Oxygen saturation is an important parameter in cases of COPD, but there are insufficient data on the role of pulse oximetry in patients with COPD, moreso in diseases across its spectrum, such as chronic bronchitis and emphysema. We assessed the p...

متن کامل

Retinal oximetry measures systemic hypoxia in central nervous system vessels in chronic obstructive pulmonary disease

BACKGROUND Determination of the blood oxyhemoglobin saturation in the retinal vessels of the eye can be achieved through spectrophotometric retinal oximetry which provides access to the state of oxyhemoglobin saturation in the central nervous system circulation. The purpose of this study was to test the capability of the Oxymap T1 oximeter to detect systemic hypoxemia and the effect of suppleme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 109 5  شماره 

صفحات  -

تاریخ انتشار 1996