Neisseria Gonorrhoeae Identification in Direct Smears by a Fluorescent Antibody-counterstain Method.

نویسندگان

  • L A WHITE
  • D S KELLOGG
چکیده

Direct smears from female patients have been considered unreliable for the detection of Neisseria gonorrhoeae by fluorescent-antibody (FA) methods because of inadequate background contrast of the fluorescent-stained smears and a scarcity of organisms on the smear. Evans blue dye employed as a counterstain eliminated the nonspecific background staining and increased the reliability of the direct FA procedure. Direct smears demonstrating positive fluorescence were obtained from 86% of a group of culturally positive named female contacts. The FA-counterstain technique is as sensitive as the presently recommended cultural procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunofluorescent antibody technique in the diagnosis of gonorrhoea by direct smears from the female.

Fry and Wilkinson (1964) demonstrated that the fluorescent antibody (FA) technique was an additional sensitive means for the identification of N. gonorrhoeae in smears of secretion from patients. The purpose of this study was to evaluate the direct staining FA technique as part of a general busy clinic routine as opposed to a reference laboratory or research technique. For this purpose commerci...

متن کامل

Immunofluorescent method for diagnosis of gonorrhoea in women.

DEACON, Peacock, Freeman, and Harris (1959) showed that the fluorescent antibody (FA) staining technique can be used to demonstrate Neisseria gonorrhoeae in specimens of secretion taken from patients suffering from gonorrhoea. Since then this technique has been widely employed for research but has been less popular for routine use as it is expensive and timeconsuming. Gallwey, Nicol, and Ridley...

متن کامل

A rapid slid coagglutination test-an alternative to the fluorescent antibody test for the identification of Neisseria gonorrhoeae.

The Phadebact(R) Gonococcus Test, a slide coagglutination test, was compared with the Difco fluorescent antibody test for the identification of Neisseria gonorrhoeae isolated from 18- to 24-hour primary plates. A total of 316 morphologically characteristic, oxidase-positive, Gram-negative diplococci were tested. Altogether 298 isolates were identified definitively as N. gonorrhoeae by a rapid c...

متن کامل

Endocervical Gram stain smears and their usefulness in the diagnosis of Chlamydia trachomatis.

OBJECTIVE To evaluate the usefulness of endocervical Gram stain smears in the diagnosis of Chlamydia trachomatis and Neisseria gonorrhoeae in a female population attending a STD clinic. METHODS 494 females attending a STD clinic and undergoing a speculum examination had endocervical specimens submitted for C trachomatis culture, direct fluorescent antibody testing (DFA), and N gonorrhoeae cul...

متن کامل

Immunofluorescence staining for the detection of Neisseria gonorrhoeae in women.

Although the use of a fluorescent antibody (FA) staining technique to demonstrate N. gonorrhoeae in secretions from patients with gonorrhoea was first described as long ago as 1959 by Deacon, Peacock, Freeman, and Harris, it does not seem to have gained wide acceptance in routine diagnosis. In our laboratory direct and delayed FA methods were first assessed in 1963 (Fry and Wilkinson, 1964). In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied microbiology

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1965