Use of a catheter-based system to measure blood flow in hemodialysis grafts during angioplasty procedures.
نویسندگان
چکیده
PURPOSE The goals of this investigation were to evaluate the accuracy and reliability of the Angioflow meter system with use of in vitro and in vivo methods and to compare it to the standard Transonics HD01 system in a clinical setting. MATERIALS AND METHODS The Angioflow meter system consists of a 6-F endovascular catheter and a laptop computer containing proprietary software for this application. Bench-top testing with use of a flow model was performed to determine the accuracy of the Angioflow meter system. Initial in vivo studies were performed with use of an animal model to assess the endovascular performance of the Angioflow meter system. Subsequently, a human clinical trial was performed to compare the Angioflow meter to the standard Transonics HD01 system. Twenty-five patients with dysfunctional (<600 mL/min) hemodialysis grafts were referred for fistulography and angioplasty. Intragraft blood flow measurements were obtained before and after angioplasty with use of both the Angioflow meter system and the Transonics HD01 system. A comparison of the two systems was performed. RESULTS Bench-top testing and animal studies demonstrated an excellent (r =.98) correlation between the measurements of the Angioflow meter and volumetric flow measurements. In the clinical trial, there was reasonable correlation (r =.72) between the blood flow measurements obtained with use of the Angioflow meter and Transonics HD01 system. The reproducibility of consecutive measurements with the Angioflow meter was excellent (r =.98). The mean increase in intragraft blood flow after angioplasty was 320 mL/min. CONCLUSION The Angioflow meter is an accurate and reliable endovascular device for measuring intragraft blood flow during interventional procedures. Use of this catheter-based system should prove beneficial for quantifying the success of endovascular interventions, the assessment of arterial inflow, and identification of inconspicuous lesions.
منابع مشابه
Invasive radiologic management of hemodialysis fistulas: measuring flow with an endovascular catheter.
OBJECTIVES To analyze the values of flow obtained with an endovascular catheter, and to determine whether they are more reliable than angiographic and clinical findings for planning and for determining the outcome of invasive radiologic treatment of hemodialysis fistulas, as well as to determine the safety of this technique during interventional radiology procedures. MATERIAL AND METHODS We u...
متن کاملVASCULAR ACCESS FOR HEMODIALYSIS: OUR EXPERIENCE WITH 3337 CASES
Over a seven year period from 1982 to 1989,3337 conduits were created in 3137 patients with end stage renal disease (ESRD) as access for chronic dialysis. These included 2690 side-to-side arteriovenous fistulae (A VF), 168 end-to-side A VFs, 10 autogenous vein grafts, 51 homogenous frozen vein grafts, 109 polytetrafluoroethylene (PTFE) grafts, 209 emergency external arteriovenous shunts, t...
متن کاملVascular access blood flow monitoring reduces access morbidity and costs.
BACKGROUND Vascular access morbidity results in suboptimal patient outcomes and costs more than $8000 per patient-year at risk, representing approximately 15% of total Medicare expenditures for ESRD patients annually. In recent years, the rate of access thrombosis has improved following the advent of vascular access blood flow monitoring (VABFM) programs to identify and treat stenosis prior to ...
متن کاملFlow in hemodialysis grafts after angioplasty: Do radiologic criteria predict success?
BACKGROUND The anatomic success of percutaneous angioplasty of venous stenosis is determined by the improvement in cross-sectional diameter of the vessel. A successful outcome is defined as a residual stenosis of <30%. The purpose of this study was to determine whether the angiographic assessment of a venous stenosis correlates with the change in graft blood flow following angioplasty. METHOD...
متن کاملEvaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz
Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular and interventional radiology : JVIR
دوره 13 4 شماره
صفحات -
تاریخ انتشار 2002